Skip to content

Candela CO2RE

CO2 Fractional/Ablative · Fractional CO2 10600nm dual-ring scanning

Technology: CO2 Fractional Laser

Classification & configurations

Category group: Resurfacing & pigment (ablative, fractional, picosecond, vascular)

Current

At a glance

New price
Not published
FDA status

Record scope: K181523 names the CO2RE Laser System and includes separate standard, fractional and surgical handpiece indications. K151655 is the earlier cited platform record. Included handpieces and applicable labeling determine scope; a platform clearance is not a statement that every accessory is supplied.

Supplies & recurring costs
See supply and replacement costs below.
View supply details
Used-market price reference
Used asking price
$25k–$45kSource not documented

Used asking prices are research references, not completed-sale values or available inventory.

Sources and data on file

Data on file

Recurring consumables
Not verified
FDA
FDA record cited — see scopeK151655, K181523
Used asking prices
Not verified
  • This panel shows a per-treatment supply cost only when a recorded figure has a dated source.
  • Bottle prices and estimates may still appear under Treatment & running costs.
  • The calculator may include a labeled planning estimate. Review it or enter your own allowance; missing data never means $0.

Figures are reference points, not current offers.

·FDA database · Updated Oct 6, 2026
Read FDA-cleared indicationsExact wording from 2 FDA records

K151655 (Syneron Medical, Ltd., 2015)

The CO2RE is indicated for use in surgical applications requiring the ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: aesthetic surgery (dermatology and plastic surgery), podiatry, gynecology, neurosurgery, orthopedics (soft tissue), arthroscopy (knee). The CO2RE is indicated for dermatological procedures requiring ablation, coagulation and resurfacing of soft tissue, including skin. The Standard Handpiece of the CO2RE System is indicated for the following: Dermatology & Plastic Surgery The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of: x laser skin resurfacing x laser dermabrasion x laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) for the treatment of: x wrinkles, rhytids, and furrows (including fines lines and texture irregularities) Clinical literature demonstrates that skin resurfacing of wrinkles, rhytids, and furrows with CO2 laser increases the amount of sub-epidermal collagen.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K181523 (Syneron-Candela Corp, 2018)

The CO2RE is indicated for use in surgical applications requiring the ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: aesthetic surgery (dermatology and plastic surgery), podiatry, gynecology, neurosurgery, orthopedics (soft tissue), arthroscopy (knee). The CO2RE is indicated for dermatological procedures requiring ablation, coagulation and resurfacing of soft tissue, including skin. The Standard Handpiece of the CO2RE System is indicated for the following: Dermatology & Plastic Surgery The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of: • laser skin resurfacing • laser dermabrasion • laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) for the treatment of: • wrinkles, rhytids, and furrows (including fines lines and texture irregularities) Clinical literature demonstrates that skin resurfacing of wrinkles, rhytids, and furrows with CO2 laser increases the amount of sub-epidermal collagen.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

Page updated: October 7, 2026 · How we verify

New-equipment price not yet documented

For a complete budget, ask for an itemized quote covering the device, accessories, training and service.

View used-price reference
Used asking price reference
Used$25k–$45k
Source not documented

Axis runs $0–$45k. Reference figures, not current offers. Used asking prices are not completed-sale values.

Consumable cost per treatment

Not verified

We hold no per-treatment consumable price for this device from a dated source. Ask the seller for a written per-treatment cost.

Price sourcesSources, dates and configurations
New: Not published·Manufacturer-provided · Updated Oct 6, 2026Price evidence review October 6, 2026: the former official CO2RE product URL redirects to Candela's general product portfolio. That page does not establish a CO2RE equipment price. The prior unsupported range is withheld pending a dated, model-specific offer. Confirm model, new-equipment availability, configuration and support directly with the supplier; this redirect alone does not prove discontinuation.
Used price reference: $25k–$45k·Researched estimate — no dated source on file yet; not a quote.
Key factsCompany, specifications and verification dates
Key facts
ManufacturerCandela (Syneron)
CompanyOwner: Apax Partners (funds advised by Apax) (private equity owned, since 2017) · Distribution: direct
Parent companyCandela Medical
Brand ownerCandela
Built by (OEM)Syneron Medical Ltd.
CategoryCO2 Fractional/Ablative
TechnologyFractional CO2 10600nm dual-ring scanning
FDA statusFDA record cited — see scope
510(k) citationK151655, K181523
New price rangeNot published
Used price reference$25k–$45k
ConsumablesNot published
Launch year2011
PricingNot published
Manufacturer-source documents checkedNot published

Overview

CO2RE is a Candela CO2 resurfacing system with adjustable treatment intensity, pattern and ablation depth. The manufacturer describes delivery to superficial and deeper skin layers, including simultaneous treatment modes.

Confirm the scanner, handpieces and model-specific labeling for the offered system.

How it worksTechnology and manufacturing

How the technology works

A 10,600nm fractional CO2; energy absorbed by tissue water ablates microscopic columns and coagulates surrounding dermis, driving collagen remodeling and tightening.

Modes — Light, Mid, Deep, Fusion — control ablation depth and density: fine lines, wrinkles, photodamage, texture, acne scars, benign lesions; a surgical handpiece supports excisional/ablative derm procedures. Fusion combines superficial and deep injury patterns in one pass.

Downtime scales from 2-3 days (Light) to 7-10 days (Deep/Fusion full-face).

Patented technology

The dual-ring scanning architecture: the scanner splits energy between the core and ring of each scan spot, allowing simultaneous treatment at two depths/intensities — the mechanism behind Fusion mode and a genuine workflow advantage. Everything else is competent conventional fractional CO2 engineering.

Origin

Developed by Syneron Medical, Yokneam, Israel; manufactured in Israel, sold/serviced by Candela (Marlborough, MA).

FDA & regulatory detailClearance timeline, authorization route and citation notes

Source and verification notes

·FDA database · Updated Oct 6, 2026Changed-field review only. K181523 names the CO2RE Laser System and includes separate standard, fractional and surgical handpiece indications. K151655 is the earlier cited platform record. Included handpieces and applicable labeling determine scope; a platform clearance is not a statement that every accessory is supplied.
Authorized via 510(k)

K181523 names the CO2RE Laser System and includes separate standard, fractional and surgical handpiece indications. K151655 is the earlier cited platform record. Included handpieces and applicable labeling determine scope; a platform clearance is not a statement that every accessory is supplied.

FDA-cleared indications (verbatim)

K151655 (Syneron Medical, Ltd., 2015)

The CO2RE is indicated for use in surgical applications requiring the ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: aesthetic surgery (dermatology and plastic surgery), podiatry, gynecology, neurosurgery, orthopedics (soft tissue), arthroscopy (knee). The CO2RE is indicated for dermatological procedures requiring ablation, coagulation and resurfacing of soft tissue, including skin. The Standard Handpiece of the CO2RE System is indicated for the following: Dermatology & Plastic Surgery The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of: x laser skin resurfacing x laser dermabrasion x laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) for the treatment of: x wrinkles, rhytids, and furrows (including fines lines and texture irregularities) Clinical literature demonstrates that skin resurfacing of wrinkles, rhytids, and furrows with CO2 laser increases the amount of sub-epidermal collagen.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K181523 (Syneron-Candela Corp, 2018)

The CO2RE is indicated for use in surgical applications requiring the ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: aesthetic surgery (dermatology and plastic surgery), podiatry, gynecology, neurosurgery, orthopedics (soft tissue), arthroscopy (knee). The CO2RE is indicated for dermatological procedures requiring ablation, coagulation and resurfacing of soft tissue, including skin. The Standard Handpiece of the CO2RE System is indicated for the following: Dermatology & Plastic Surgery The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of: • laser skin resurfacing • laser dermabrasion • laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) for the treatment of: • wrinkles, rhytids, and furrows (including fines lines and texture irregularities) Clinical literature demonstrates that skin resurfacing of wrinkles, rhytids, and furrows with CO2 laser increases the amount of sub-epidermal collagen.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

Marketed for

CO2 fractional — Fractional CO2 10600nm dual-ring scanning

Marketing claims are the manufacturer's own and are not the same as a cleared indication.

Parent company: Candela Medical

Legal manufacturer: Syneron Medical Ltd. (Israel)

Applicant on the FDA record

Syneron Medical, Ltd.The applicant named on the FDA record can differ from the brand shown on the device.

Regulatory data comes from public FDA records and may lag recent updates. Confirm the applicable status and documentation before purchase.

Treatment & running costs

Supplies & recurring costs

Supply pricing is not documented with a dated source yet. Request an itemized supply quote.

Not yet documented: session schedule, treatment pricing, annual service costs.

Payback calculatorEnter your quote, volume and running costs

Estimate your payback

Enter your quote and treatment costs for Candela CO2RE. Published figures appear where available; review them before using the estimate.

Start from

No verified per-treatment supply cost is on file. Enter your own allowance. Use $0 only if you have confirmed that it applies to your practice.

New price not published — enter the number on your quote.

20 is an illustrative default — change it to your volume.

No sourced per-session price on file — enter what you charge.

Required — enter your cost; missing data does not mean $0.

Required — include staff time and your own time. Enter 0 only to explicitly exclude labor from this estimate.

Annual service contract ÷ 12, if you carry one.

Your estimate

Enter purchase price, price you charge per treatment, consumable cost per treatment, labor cost per treatment to see contribution and a payback range.

This model ignores financing — if you lease or borrow, add your monthly payment. Estimates from your inputs and our published ranges — not a projection, guarantee or financial advice. How we calculate this.

Screening considerationsCatalog notes to check against the current instructions for use

Catalog screening notes

Recent isotretinoin, keloid history, active infection with mandatory HSV prophylaxis, Fitzpatrick IV-VI (PIH risk), impaired wound healing (diabetes, immunosuppression, smoking), recent deep peels or radiation. Downtime tolerance and sun-avoidance compliance are part of candidacy.

These notes are not a complete or verified manufacturer contraindication list. Use the current instructions for the exact device and applicator to determine contraindications, warnings and patient eligibility.

Warranty & serviceWhat to confirm in writing before you buy

Published warranty details

Candela’s FAQ makes coverage dependent on the device and contract. Request CO2RE terms for the laser source, delivery accessories, labor, travel and any used-unit inspection.

A current warranty duration, annual contract price and laser-source replacement price remain unverified here.

·Manufacturer-provided · Updated Oct 7, 2026
Source notes

Published FAQ does not establish CO2RE-specific warranty or repair prices. Removes unsupported service rankings and replacement-cost assumptions.

Reviewed warranty/service scope only; no full-profile or current equipment-price verification.

Before buying new or used, confirm in writing:

  • Current warranty coverage
  • Included training
  • Service terms

Chains using this device

A chain listing does not establish availability at every location.

No confirmed chain deployments recorded yet.

Owner & operator reviews

Write a review

No owner or operator reviews yet. Be the first →

Current alternatives

Current catalog models to research. Confirm availability and configuration with the supplier.

Alma Hybrid

CO2 Fractional/Ablative

New-equipment price not yet documented.

Cynosure Lutronic eCO2 3D

CO2 Fractional/Ablative

New-equipment price not yet documented.

Research comparisons

Includes current and older models.

History10 tracked changes

Every tracked change to pricing, lifecycle status, FDA data and warranty terms — newest first.

  1. October 7, 2026

    Warranty & service

    Source: Catalog update

  2. October 7, 2026

    Warranty and service source review 2026-10-07

    Published FAQ does not establish CO2RE-specific warranty or repair prices. Removes unsupported service rankings and replacement-cost assumptions. Equipment purchase prices, FDA records and whole-profile verification dates are unchanged.

    Source: https://shop.candelamedical.com/pages/faqs

  3. October 6, 2026

    FDA indication

    Source: Catalog update

  4. October 6, 2026

    FDA source URL

    https://www.accessdata.fda.gov/cdrh_docs/pdf18/K181523.pdf

    Source: Catalog update

  5. October 6, 2026

    Council batch 01 follow-up corrections

    Reviewed changed fields only on October 6, 2026. Unchanged equipment prices and other fields are not reverified. Source regions and model generations must not be generalized.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf18/K181523.pdf

  6. October 6, 2026

    fda status council batch 01 follow-up evidence

    Claim-specific evidence; not a whole-profile verification.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf18/K181523.pdf

  7. October 6, 2026

    Source-based product overview

    Manufacturer-source review of overview and/or link on October 6, 2026. Pricing, regulatory records and current sales availability are not independently verified by this edit.

    Source: https://marketing.candelamedical.com/EMEA-UK-WB-2021-02-Hamish-McNair_On-Demand.html?country-language=Default

  8. October 6, 2026

    New price range

    90000-120000 → —

    Source: Catalog update

  9. October 6, 2026

    Price evidence review

    Price evidence review October 6, 2026: the former official CO2RE product URL redirects to Candela's general product portfolio. That page does not establish a CO2RE equipment price. The prior unsupported range is withheld pending a dated, model-specific offer. Confirm model, new-equipment availability, configuration and support directly with the supplier; this redirect alone does not prove discontinuation.

    Source: https://candelamedical.com/products/co2re/

  10. August 1, 2026

    Record created

    Added to The Aesthetic Index — August 2026

    Source: The Aesthetic Index editorial

Cite this data: The Aesthetic Index, "Candela CO2RE — pricing, FDA status and cost to own", aestheticindex.co (accessed November 23, 2026).

Get the full State of Aesthetic Devices 2026 report

A catalog of US-marketed aesthetic and wellness devices — preview it free.

Get the report

Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.