Sciton ProLipo Plus
Laser lipolysis (internal) · 1064+1319nm laser lipolysis module
Technology: Laser Lipolysis
At a glance
- New-unit reference · older model
- Not published
- Used asking price
- $10k–$25kSource not documented
- FDA status
- Supplies & recurring costs
- Supply details not yet documented.
Sources and verified data on file
Data on file
- Recurring consumables
- Not verified
- Used asking prices
- Not verified
- This panel shows a per-treatment supply cost only when a recorded figure has a dated source.
- Bottle prices and estimates may still appear under Treatment & running costs.
- The calculator may include a labeled planning estimate. Review it or enter your own allowance; missing data never means $0.
Figures are reference points, not current offers. Used asking prices are not completed-sale values.
Read FDA-cleared indicationsExact wording from 2 FDA records
K081352 (Sciton, Inc, 2008)
755 nm Indications for Use: The 755 nm Profile Multi-Platform System with its accessories is indicated for stable long-term, or permanent hair reduction for all skin types (Fitzpatrick I - VI) including tanned skin. It is also indicated for the treatment of vascular lesions, benign pigmented lesions and wrinkles. 1320 nm Indications for Use: The 1320nm Profile Multi-Platform System with its accessories is intended for the surgical incision, excision, vaporization, ablation, and coagulation of soft tissue. Soft tissue includes skin, cutaneous tissue, subcutaneous tissue, striated and smooth tissue, muscle, cartilage meniscus, mucous membrane, lymph vessels and nodes, organs and glands. The Profile 1320nm laser is further indicated for laser assisted lipolysis. 2940 nm Indications for Use: The 2940 nm Profile Multi-Platform System with Profractional handpiece and delivery system is intended for use in dermatological procedures requiring skin resurfacing and coagulation of soft tissue.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
K101916 (Sciton, Inc, 2011)
The 755 nm Alexandrite system is designed for use in: The ClearScan ALX 755nm Alexandrite laser system with its accessories is indicated for stable long-term, or permanent hair reduction for all skin types (Fitzpatrick I - VI) including tanned skin. It is also indicated for the treatment of vascular lesions, benign pigmented lesions and wrinkles. Q-Switched 755 nrn Alexandrite Indications for Use: The JOULE 0-Switched 755 nm Alex Multi-Platform Systems with accessories are indicated for the following uses: Pigmented Lesions Tattoos The 1064 nm Nd:YAG Indications for Use: Coagulation and hemostasis of benign vascular lesions such as, but not limited to, telangiectasias and rosacea. Removal of unwanted hair (for stable, long term or permanent hair reduction) through selective targeting of melanin in hair follictes and for the treatment of Pseudlofolliculitis Barbae (PFB). Treatment of facial wrinkles. The JOULE 1064 nm Nd:YAG with fiber delivery is indicated for laser assisted lipolysis.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
Page updated: September 8, 2026 · How we verify
No new-unit price reference is published for this older model.
Axis runs $0–$25k. Reference figures, not current offers. Used asking prices are not completed-sale values.
Not verified
We hold no per-treatment consumable price for this device from a dated source. Ask the seller for a written per-treatment cost.
Price sourcesSources, dates and configurations
Key factsCompany, specifications and verification dates
| Manufacturer | Sciton |
|---|---|
| Company | Owner: Employee-owned (co-founders James Hobart and Daniel Negus) (family / founder owned, since 1997) · Distribution: direct |
| Parent company | Sciton |
| Brand owner | Sciton |
| Built by (OEM) | Sciton Inc. |
| Category | Body Contouring |
| Technology | 1064+1319nm laser lipolysis module |
| FDA status | FDA Cleared |
| 510(k) citation | K081352, K101916 |
| New-unit reference (older model) | Not published |
| Used asking range | $10k–$25k |
| Consumables | Not published |
| Launch year | 2009 |
| Pricing | Not published |
| Manufacturer-source documents checked | Not published |
Overview
Module on Joule platform
FDA & regulatory detailClearance timeline, authorization route and citation notes
Launch 2009 · Clearance 2026 · K081352; K101916
Platform clearance: K081352 (Profile Multi-Platform System, decision 23 Oct 2008 — 1320 nm module indicated for laser-assisted lipolysis) and K101916 (JOULE Multi-Platform System, 18 Mar 2011 — 1064/1319 nm modules incl. laser-assisted lipolysis); no 510(k) naming ProLipo was located. Checked 8 Sep 2026.
FDA-cleared indications (verbatim)
K081352 (Sciton, Inc, 2008)
755 nm Indications for Use: The 755 nm Profile Multi-Platform System with its accessories is indicated for stable long-term, or permanent hair reduction for all skin types (Fitzpatrick I - VI) including tanned skin. It is also indicated for the treatment of vascular lesions, benign pigmented lesions and wrinkles. 1320 nm Indications for Use: The 1320nm Profile Multi-Platform System with its accessories is intended for the surgical incision, excision, vaporization, ablation, and coagulation of soft tissue. Soft tissue includes skin, cutaneous tissue, subcutaneous tissue, striated and smooth tissue, muscle, cartilage meniscus, mucous membrane, lymph vessels and nodes, organs and glands. The Profile 1320nm laser is further indicated for laser assisted lipolysis. 2940 nm Indications for Use: The 2940 nm Profile Multi-Platform System with Profractional handpiece and delivery system is intended for use in dermatological procedures requiring skin resurfacing and coagulation of soft tissue.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
K101916 (Sciton, Inc, 2011)
The 755 nm Alexandrite system is designed for use in: The ClearScan ALX 755nm Alexandrite laser system with its accessories is indicated for stable long-term, or permanent hair reduction for all skin types (Fitzpatrick I - VI) including tanned skin. It is also indicated for the treatment of vascular lesions, benign pigmented lesions and wrinkles. Q-Switched 755 nrn Alexandrite Indications for Use: The JOULE 0-Switched 755 nm Alex Multi-Platform Systems with accessories are indicated for the following uses: Pigmented Lesions Tattoos The 1064 nm Nd:YAG Indications for Use: Coagulation and hemostasis of benign vascular lesions such as, but not limited to, telangiectasias and rosacea. Removal of unwanted hair (for stable, long term or permanent hair reduction) through selective targeting of melanin in hair follictes and for the treatment of Pseudlofolliculitis Barbae (PFB). Treatment of facial wrinkles. The JOULE 1064 nm Nd:YAG with fiber delivery is indicated for laser assisted lipolysis.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
Marketed for
Injection lipolysis / laser lipo — 1064+1319nm laser lipolysis module
Marketing claims are the manufacturer's own and are not the same as a cleared indication.
Parent company: Sciton
Legal manufacturer: Sciton Inc. (United States)
Applicant on the FDA record
Sciton, Inc.The applicant named on the FDA record can differ from the brand shown on the device.
Regulatory data comes from public FDA records and may lag recent updates. Confirm the applicable status and documentation before purchase.
Treatment & running costs
Treatments
Sessions & timing
No treatment schedule documented yet.
What practices charge
No sourced treatment price on file.
Supplies & recurring costs
Consumable costs are not documented yet.
Annual service & support
No annual service cost documented yet.
Payback calculatorModel your own volume, labor and service costs
Estimate your payback
Pre-filled from our published Sciton ProLipo Plus data where we have it. Estimates appear once the required inputs are available. Review and adjust every pre-filled value before relying on the result.
Start from
No verified per-treatment supply cost is on file. Enter your own allowance. Use $0 only if you have confirmed that it applies to your practice.
Pre-filled from the midpoint of the published used asking range
20 is an illustrative default — change it to your volume.
No sourced per-session price on file — enter what you charge.
Required — enter your cost; missing data does not mean $0.
Provider or tech time for one treatment, fully loaded. Enter 0 if you own-operate.
Annual service contract ÷ 12, if you carry one.
Your estimate
Enter price you charge per treatment, consumable cost per treatment to see contribution and a payback range.
This model ignores financing — if you lease or borrow, add your monthly payment. Estimates from your inputs and our published ranges — not a projection, guarantee or financial advice. How we calculate this.
Warranty & serviceWhat to confirm in writing before you buy
Before buying new or used, confirm in writing:
- Current warranty coverage
- Included training
- Service terms
Chains using this device
A chain listing does not establish availability at every location.
No confirmed chain deployments recorded yet.
Owner & operator reviews
Write a reviewNo owner or operator reviews yet. Be the first →
Current alternatives
Current catalog models to research. Confirm availability and configuration with the supplier.
History10 tracked changes
Every tracked change to pricing, lifecycle status, FDA data and warranty terms — newest first.
September 8, 2026
FDA status
Unknown → Cleared
Source: Record correction
September 8, 2026
FDA source URL
https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K081352
Source: Record correction
September 8, 2026
FDA K-numbers
K081352; K101916
Source: Record correction
September 4, 2026
FDA status
Source: Catalog update
September 4, 2026
FDA indication
Source: Catalog update
September 4, 2026
FDA status
No US 510(k) naming this model located; cleared assertion removed
Source: Council round 2 audit, verified on openFDA 2026-09-04
August 9, 2026
FDA status
Source: Catalog update
August 5, 2026
FDA indication
Source: Catalog update
August 5, 2026
FDA status
Unknown → Cleared
Source: Catalog update
August 1, 2026
Record created
Added to The Aesthetic Index — August 2026
Source: The Aesthetic Index editorial
Cite this data: The Aesthetic Index, "Sciton ProLipo Plus — pricing, FDA status and cost to own", aestheticindex.co (accessed September 24, 2026).
Get the full State of Aesthetic Devices 2026 report
A catalog of US-marketed aesthetic and wellness devices — preview it free.
Explore this model’s specs and owner reviews. For new-equipment inquiries, browse current models.
Browse current modelsDevice and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.