Skip to content

Syneron/Candela eTwo

Fractional RF (non-needle) · Sublative (eMatrix) + Sublime (IR+RF)

Classification & configurations

Category group: Skin tightening & remodeling (RF microneedling, monopolar RF, HIFU)

Discontinued

At a glance

New-unit reference · older model
Not published
Used asking price
$6k–$15kSource not documented
FDA status

Record scope: K141507 separates the applicators: Sublative RF covers skin ablation/resurfacing and facial wrinkles; Sublime covers non-invasive wrinkle treatment. Above 62 mJ/pin for Sublative RF and above 100 J/cm³ for Sublime, the indication limits use to skin types I–IV. Match the exact applicator and energy setting to its labeling; do not infer a blanket all-skin-types claim.

Supplies & recurring costs
See supply and replacement costs below.
View supply details
Sources and data on file

Data on file

Recurring consumables
Not verified
FDA
FDA record cited — see scopeK110672, K141507
Used asking prices
Not verified
  • This panel shows a per-treatment supply cost only when a recorded figure has a dated source.
  • Bottle prices and estimates may still appear under Treatment & running costs.
  • The calculator may include a labeled planning estimate. Review it or enter your own allowance; missing data never means $0.

Figures are reference points, not current offers. Used asking prices are not completed-sale values.

·FDA database · Updated Oct 7, 2026
Read FDA-cleared indicationsExact wording from 2 FDA records

K110672 (Syneron, Ltd., 2011)

STATEMENT eTwo Skin Treatment System procedures. The Sublative RF applicator is indicated for Dermatological procedures requiring ablation and resurfacing of the skin, and for the treatment of facial wrinkles. The Sublime applicator is indicated for non invasive wrinkles treatment.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K141507 (Syneron Medical, Ltd., 2014)

The eTwo Skin Treatment System is intended for dermatological procedures. The Sublative RF applicator is indicated for dermatological procedures requiring ablation and resurfacing of the skin, and for the treatment of facial wrinkles. At higher energy levels greater than 62 mJ/pin, the Sublative RF applicator is limited to skin types I-IV. The Sublime applicator is indicated for non-invasive wrinkles treatment. At higher energy levels greater than 100 J/cm3, the Sublime applicator is limited to skin types I-IV.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

Page updated: October 7, 2026 · How we verify

Older-model price not documented

Use the ownership information below and compare current models.

Used asking price reference
Used$6k–$15k
Source not documented

Axis runs $0–$15k. Reference figures, not current offers. Used asking prices are not completed-sale values.

Consumable cost per treatment

Not verified

We hold no per-treatment consumable price for this device from a dated source. Ask the seller for a written per-treatment cost.

Price sourcesSources, dates and configurations
Used price reference: $6k–$15k·Researched estimate — no dated source on file yet; not a quote.
Key factsCompany, specifications and verification dates
Key facts
ManufacturerSyneron-Candela
CompanyOwner: Apax Partners (funds advised by Apax) (private equity owned, since 2017) · Distribution: direct
Parent companyCandela Medical
Brand ownerSyneron/Candela
Built by (OEM)Syneron Medical Ltd.
CategoryFractional RF (non-needle)
TechnologySublative (eMatrix) + Sublime (IR+RF)
FDA statusFDA record cited — see scope
510(k) citationK110672, K141507
New-unit reference (older model)Not published
Used price reference$6k–$15k
ConsumablesNot published
Launch year2012
PricingNot published
Manufacturer-source documents checkedNot published

Overview

eTwo combines two distinct applicators: Sublative RF for fractional skin ablation/resurfacing, and Sublime for non-invasive wrinkle treatment. The later clearance includes skin-type limitations at higher energy levels.

Visit product website (marketing.candelamedical.com)

FDA & regulatory detailClearance timeline, authorization route and citation notes

Source and verification notes

·FDA database · Updated Oct 7, 2026K141507 indication enclosure, PDF page 3, visually checked October 7, 2026. Adds the exact greater-than energy thresholds to existing applicator-specific scope; no change to clearance status or other device specifications. Previous source context: K141507 separates the applicators: Sublative RF covers skin ablation/resurfacing and facial wrinkles; Sublime covers non-invasive wrinkle treatment. At higher energy levels, the record limits both applicators to skin types I–IV. Use the exact applicator labeling, not a blanket all-skin-types claim. Additional sources: FDA document. Only the stated fields were reviewed; not whole-profile verification.
Authorized via 510(k)

K141507 separates the applicators: Sublative RF covers skin ablation/resurfacing and facial wrinkles; Sublime covers non-invasive wrinkle treatment. Above 62 mJ/pin for Sublative RF and above 100 J/cm³ for Sublime, the indication limits use to skin types I–IV. Match the exact applicator and energy setting to its labeling; do not infer a blanket all-skin-types claim.

FDA-cleared indications (verbatim)

K110672 (Syneron, Ltd., 2011)

STATEMENT eTwo Skin Treatment System procedures. The Sublative RF applicator is indicated for Dermatological procedures requiring ablation and resurfacing of the skin, and for the treatment of facial wrinkles. The Sublime applicator is indicated for non invasive wrinkles treatment.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K141507 (Syneron Medical, Ltd., 2014)

The eTwo Skin Treatment System is intended for dermatological procedures. The Sublative RF applicator is indicated for dermatological procedures requiring ablation and resurfacing of the skin, and for the treatment of facial wrinkles. At higher energy levels greater than 62 mJ/pin, the Sublative RF applicator is limited to skin types I-IV. The Sublime applicator is indicated for non-invasive wrinkles treatment. At higher energy levels greater than 100 J/cm3, the Sublime applicator is limited to skin types I-IV.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

Marketed for

Fractional RF (non-needle) — Sublative (eMatrix) + Sublime (IR+RF)

Marketing claims are the manufacturer's own and are not the same as a cleared indication.

Parent company: Candela Medical

Legal manufacturer: Syneron Medical Ltd. (Israel)

Applicant on the FDA record

Syneron, Ltd.The applicant named on the FDA record can differ from the brand shown on the device.

Regulatory data comes from public FDA records and may lag recent updates. Confirm the applicable status and documentation before purchase.

Treatment & running costs

Supplies & recurring costs

Candela’s 2019 Asia-Pacific eTwo brochure lists disposable Sublative iD Standard 64-pin tips in 100- and 400-pulse versions, and a Focal 44-pin tip with 200 pulses. These are tip allowances, not a verified number of complete treatments.

Confirm the exact applicator, compatible tip part number and current US price; this regional brochure does not establish current US availability or per-treatment cost.

·Manufacturer-provided · Updated Oct 7, 2026
Source notes

Candela-hosted 2019 eTwo brochure PU02481EN-CN Rev00, pages 1–2, identifies disposable Sublative iD variants and pulse allowances. Regional historical documentation only; no extension to eMatrix, current US stock, treatment yield or unit price.

Not yet documented: session schedule, treatment pricing, annual service costs.

Payback calculatorEnter your quote, volume and running costs

Estimate your payback

Enter your quote and treatment costs for Syneron/Candela eTwo. Published figures appear where available; review them before using the estimate.

Start from

No verified per-treatment supply cost is on file. Enter your own allowance. Use $0 only if you have confirmed that it applies to your practice.

Pre-filled from the midpoint of the published used asking range

20 is an illustrative default — change it to your volume.

No sourced per-session price on file — enter what you charge.

Required — enter your cost; missing data does not mean $0.

Required — include staff time and your own time. Enter 0 only to explicitly exclude labor from this estimate.

Annual service contract ÷ 12, if you carry one.

Your estimate

Enter price you charge per treatment, consumable cost per treatment, labor cost per treatment to see contribution and a payback range.

This model ignores financing — if you lease or borrow, add your monthly payment. Estimates from your inputs and our published ranges — not a projection, guarantee or financial advice. How we calculate this.

Warranty & serviceWhat to confirm in writing before you buy

Before buying new or used, confirm in writing:

  • Current warranty coverage
  • Included training
  • Service terms

Chains using this device

A chain listing does not establish availability at every location.

No confirmed chain deployments recorded yet.

Owner & operator reviews

Write a review

No owner or operator reviews yet. Be the first →

Current alternatives

Current catalog models to research. Confirm availability and configuration with the supplier.

EndyMed FSR handpiece

Fractional RF (non-needle)

New-equipment price not yet documented.

History8 tracked changes

Every tracked change to pricing, lifecycle status, FDA data and warranty terms — newest first.

  1. October 7, 2026

    FDA indication

    Source: Catalog update

  2. October 7, 2026

    Council Batch 04 reconciliation 2026-10-07

    K141507 indication enclosure, PDF page 3, visually checked October 7, 2026. Adds the exact greater-than energy thresholds to existing applicator-specific scope; no change to clearance status or other device specifications.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf14/K141507.pdf

  3. October 7, 2026

    Batch04 manufacturer documentation follow-up 2026-10-07

    Candela-hosted 2019 eTwo brochure PU02481EN-CN Rev00, pages 1–2, identifies disposable Sublative iD variants and pulse allowances. Regional historical documentation only; no extension to eMatrix, current US stock, treatment yield or unit price. Equipment prices, FDA fields and whole-profile verification dates are unchanged.

    Source: https://marketing.candelamedical.com/rs/620-HCU-218/images/PU02481EN-CN_Rev00_APAC_eTwoBrochure%28Asian%29_LRPDF_2019%20%281%29.pdf

  4. October 7, 2026

    FDA indication

    Source: Catalog update

  5. October 7, 2026

    FDA source URL

    https://www.accessdata.fda.gov/cdrh_docs/pdf14/K141507.pdf

    Source: Catalog update

  6. October 7, 2026

    Batch 04 primary-source corrections

    Reviewed changed fields only on October 7, 2026. Unchanged equipment prices and other fields are not reverified. Scope, generation, region and offer terms remain specific to each source. Additional sources: https://www.accessdata.fda.gov/cdrh_docs/pdf11/K110672.pdf

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf14/K141507.pdf

  7. October 7, 2026

    fda status batch 04 primary-source evidence

    Claim-specific evidence; not a whole-profile verification.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf14/K141507.pdf

  8. August 1, 2026

    Record created

    Added to The Aesthetic Index — August 2026

    Source: The Aesthetic Index editorial

Cite this data: The Aesthetic Index, "Syneron/Candela eTwo — pricing, FDA status and cost to own", aestheticindex.co (accessed November 23, 2026).

Get the full State of Aesthetic Devices 2026 report

A catalog of US-marketed aesthetic and wellness devices — preview it free.

Get the report

Explore this model’s specs and owner reviews. For new-equipment inquiries, browse current models.

Browse current models

Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.