Syneron/Candela eMatrix (Sublative)
Fractional RF (non-needle) · Fractional bipolar RF resurfacing
Classification & configurations
Category group: Skin tightening & remodeling (RF microneedling, monopolar RF, HIFU)
At a glance
- New-unit reference · older model
- Not published
- Used asking price
- $4k–$12kSource not documented
- FDA status
Record scope: K073572 and K090025 name the Matrix RF applicator. The latter adds facial wrinkles to skin ablation/resurfacing. Surface electrode-pin delivery does not make the procedure risk-free or establish that it is safer or cheaper than RF microneedling.
- Supplies & recurring costs
- See supply and replacement costs below.
Sources and data on file
Data on file
- Recurring consumables
- Not verified
- Used asking prices
- Not verified
- This panel shows a per-treatment supply cost only when a recorded figure has a dated source.
- Bottle prices and estimates may still appear under Treatment & running costs.
- The calculator may include a labeled planning estimate. Review it or enter your own allowance; missing data never means $0.
Figures are reference points, not current offers. Used asking prices are not completed-sale values.
Read FDA-cleared indicationsExact wording from 2 FDA records
K073572 (Syneron Medical, Ltd., 2008)
The Matrix RF Applicator is intended for dermatological procedures requiring ablation and resurfacing of the skin.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
K090025 (Syneron Medical, Ltd., 2010)
The Matrix RE Applicator is intended for dermatological procedures requiring ablation and resurfacing of the skin, and for the treatment of facial wrinkles.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
Page updated: October 7, 2026 · How we verify
Older-model price not documented
Use the ownership information below and compare current models.
Axis runs $0–$12k. Reference figures, not current offers. Used asking prices are not completed-sale values.
Not verified
We hold no per-treatment consumable price for this device from a dated source. Ask the seller for a written per-treatment cost.
Price sourcesSources, dates and configurations
Key factsCompany, specifications and verification dates
| Manufacturer | Syneron-Candela |
|---|---|
| Company | Owner: Apax Partners (funds advised by Apax) (private equity owned, since 2017) · Distribution: direct |
| Parent company | Candela Medical |
| Brand owner | Syneron/Candela |
| Built by (OEM) | Syneron Medical Ltd. |
| Category | Fractional RF (non-needle) |
| Technology | Fractional bipolar RF resurfacing |
| FDA status | FDA record cited — see scope |
| 510(k) citation | K073572, K090025 |
| New-unit reference (older model) | Not published |
| Used price reference | $4k–$12k |
| Consumables | Not published |
| Launch year | 2010 |
| Pricing | Not published |
| Manufacturer-source documents checked | Not published |
Overview
eMatrix uses the Matrix RF applicator to deliver bipolar RF through an array of surface electrode pins and disposable tips. The cited indication includes skin ablation/resurfacing and facial wrinkles; confirm tip supply and system labeling.
How it worksTechnology and manufacturing
How the technology works
Sublative uses fractionated bipolar RF delivered through a multi-electrode tip pressed against the skin — energy arcs into the tissue in a pyramid shape, so the deeper dermis receives proportionally more heat than the surface.
That "sublative" inversion (more heat below, less ablation above) is the opposite of fractional lasers and is why downtime is 1-2 days of redness and grid marks rather than a week of oozing. Because RF is chromophore-blind, it's meaningfully safer than fractional lasers on Fitzpatrick IV-VI.
Results on texture, mild acne scarring, and fine lines are real but modest — think three to five sessions for what a CO2 does in one.
Patented technology
Syneron built its whole company on patented elōs and fractionated bipolar RF electrode-array delivery; the Sublative tip geometry that concentrates energy sub-epidermally is the signature IP here. No optical component, no needles — just electrodes.
Origin
Israel (Syneron Medical, Yokneam; now Candela Corporation, Marlborough, MA as US parent).
FDA & regulatory detailClearance timeline, authorization route and citation notes
Source and verification notes
·FDA database · Updated Oct 7, 2026K073572 and K090025 name the Matrix RF applicator. The latter adds facial wrinkles to skin ablation/resurfacing. Surface electrode-pin delivery does not make the procedure risk-free or establish that it is safer or cheaper than RF microneedling. Additional sources: FDA document. Only the stated fields were reviewed; not whole-profile verification.K073572 and K090025 name the Matrix RF applicator. The latter adds facial wrinkles to skin ablation/resurfacing. Surface electrode-pin delivery does not make the procedure risk-free or establish that it is safer or cheaper than RF microneedling.
FDA-cleared indications (verbatim)
K073572 (Syneron Medical, Ltd., 2008)
The Matrix RF Applicator is intended for dermatological procedures requiring ablation and resurfacing of the skin.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
K090025 (Syneron Medical, Ltd., 2010)
The Matrix RE Applicator is intended for dermatological procedures requiring ablation and resurfacing of the skin, and for the treatment of facial wrinkles.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
Marketed for
Fractional RF (non-needle) — Fractional bipolar RF resurfacing
Marketing claims are the manufacturer's own and are not the same as a cleared indication.
Parent company: Candela Medical
Legal manufacturer: Syneron Medical Ltd. (Israel)
Applicant on the FDA record
Syneron Medical, Ltd.The applicant named on the FDA record can differ from the brand shown on the device.
Regulatory data comes from public FDA records and may lag recent updates. Confirm the applicable status and documentation before purchase.
Treatment & running costs
Supplies & recurring costs
Supply pricing is not documented with a dated source yet. Request an itemized supply quote.
Not yet documented: session schedule, treatment pricing, annual service costs.
Payback calculatorEnter your quote, volume and running costs
Estimate your payback
Enter your quote and treatment costs for Syneron/Candela eMatrix (Sublative). Published figures appear where available; review them before using the estimate.
Start from
No verified per-treatment supply cost is on file. Enter your own allowance. Use $0 only if you have confirmed that it applies to your practice.
Pre-filled from the midpoint of the published used asking range
20 is an illustrative default — change it to your volume.
No sourced per-session price on file — enter what you charge.
Required — enter your cost; missing data does not mean $0.
Required — include staff time and your own time. Enter 0 only to explicitly exclude labor from this estimate.
Annual service contract ÷ 12, if you carry one.
Your estimate
Enter price you charge per treatment, consumable cost per treatment, labor cost per treatment to see contribution and a payback range.
This model ignores financing — if you lease or borrow, add your monthly payment. Estimates from your inputs and our published ranges — not a projection, guarantee or financial advice. How we calculate this.
Screening considerationsCatalog notes to check against the current instructions for use
Catalog screening notes
Pacemakers/ICDs and any implanted electronic device, metal implants in the field, pregnancy, active infection or eczema in the treatment area, and recent isotretinoin. Darker skin tolerates it well, but stacking pulses can still blister and cause PIH.
These notes are not a complete or verified manufacturer contraindication list. Use the current instructions for the exact device and applicator to determine contraindications, warnings and patient eligibility.
Warranty & serviceWhat to confirm in writing before you buy
Published warranty details
Confirm current eMatrix support and parts availability with Candela using the unit’s serial number. Candela says warranty coverage varies by device and contract; the general FAQ does not establish legacy eMatrix eligibility.
Obtain written reseller coverage and repair estimates instead of assuming a standard warranty or repair-cost ceiling.
Source notes
Removes an unverified end-of-support assertion, claims of plentiful parts and unsupported repair/applicator prices. Current exact-unit support remains unresolved; the FAQ is not proof of eMatrix support.
Reviewed warranty/service scope only; no full-profile or current equipment-price verification.
Before buying new or used, confirm in writing:
- Current warranty coverage
- Included training
- Service terms
Chains using this device
A chain listing does not establish availability at every location.
No confirmed chain deployments recorded yet.
Owner & operator reviews
Write a reviewNo owner or operator reviews yet. Be the first →
Current alternatives
Current catalog models to research. Confirm availability and configuration with the supplier.
History9 tracked changes
Every tracked change to pricing, lifecycle status, FDA data and warranty terms — newest first.
October 7, 2026
Warranty & service
Source: Catalog update
October 7, 2026
Warranty and service source review 2026-10-07
Removes an unverified end-of-support assertion, claims of plentiful parts and unsupported repair/applicator prices. Current exact-unit support remains unresolved; the FAQ is not proof of eMatrix support. Equipment purchase prices, FDA records and whole-profile verification dates are unchanged.
Source: https://shop.candelamedical.com/pages/faqs
October 7, 2026
FDA indication
Source: Catalog update
October 7, 2026
FDA source URL
https://www.accessdata.fda.gov/cdrh_docs/pdf9/K090025.pdf
Source: Catalog update
October 7, 2026
fda status batch 04 primary-source evidence
Claim-specific evidence; not a whole-profile verification.
Source: https://www.accessdata.fda.gov/cdrh_docs/pdf9/K090025.pdf
September 4, 2026
consumables detail
Manufacturer-conduct language removed or restated as a dated, sourced fact.
Source: Editorial sweep 2026-09-04: manufacturer-conduct language neutralized
September 4, 2026
contraindications
Manufacturer-conduct language removed or restated as a dated, sourced fact.
Source: Editorial sweep 2026-09-04: manufacturer-conduct language neutralized
August 5, 2026
Warranty & service
Source: Catalog update
August 1, 2026
Record created
Added to The Aesthetic Index — August 2026
Source: The Aesthetic Index editorial
Cite this data: The Aesthetic Index, "Syneron/Candela eMatrix (Sublative) — pricing, FDA status and cost to own", aestheticindex.co (accessed November 23, 2026).
Get the full State of Aesthetic Devices 2026 report
A catalog of US-marketed aesthetic and wellness devices — preview it free.
Explore this model’s specs and owner reviews. For new-equipment inquiries, browse current models.
Browse current modelsDevice and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.