Sciton Contour TRL (Joule/mJoule module)
Er:YAG Resurfacing · Er:YAG 2940nm tunable full-field
Technology: Erbium Laser
Classification & configurations
Category group: Resurfacing & pigment (ablative, fractional, picosecond, vascular)
At a glance
- New price
- Not published
- FDA status
Record scope: K101916 covers JOULE with multiple wavelength-specific applications. Its 2940 nm section includes resurfacing and wrinkles and separately describes ProFractional delivery. It does not by itself establish that every JOULE or mJOULE includes the marketed Contour TRL module. Confirm console and scanner compatibility.
- Supplies & recurring costs
- Supply details not yet documented.
Sources and data on file
Data on file
- Recurring consumables
- Not verified
- FDA
- FDA record cited — see scopeK101916
- Used asking prices
- Not verified
- This panel shows a per-treatment supply cost only when a recorded figure has a dated source.
- Bottle prices and estimates may still appear under Treatment & running costs.
- The calculator may include a labeled planning estimate. Review it or enter your own allowance; missing data never means $0.
Figures are reference points, not current offers.
Read FDA-cleared indicationsExact wording from 1 FDA record
K101916 (Sciton, Inc, 2011)
The 755 nm Alexandrite system is designed for use in: The ClearScan ALX 755nm Alexandrite laser system with its accessories is indicated for stable long-term, or permanent hair reduction for all skin types (Fitzpatrick I - VI) including tanned skin. It is also indicated for the treatment of vascular lesions, benign pigmented lesions and wrinkles. Q-Switched 755 nm Alexandrite Indications for Use: The JOULE Q-Switched 755 nm Alex Multi-Platform Systems with accessories are indicated for the following uses: Pigmented Lesions Tattoos The 1064 nm Nd:YAG Indications for Use: Coagulation and hemostasis of benign vascular lesions such as, but not limited to, telangiectasias and rosacea. Removal of unwanted hair (for stable, long term or permanent hair reduction) through selective targeting of melanin in hair follicles and for the treatment of Pseudofolliculitis Barbae (PFB). Treatment of facial wrinkles. The JOULE 1064 nm Nd:YAG with fiber delivery is indicated for laser assisted lipolysis. […] 2940 nm Indications for Use: The JOULE 2940 nm Multi-Platform Systems with delivery accessories are designed for use in surgical applications requiring the excision, incision, ablation, vaporization, and coagulation of soft tissue, and for skin resurfacing. Aesthetic Surgery: Skin resurfacing and treatment of wrinkles. Dermatology & Plastic Surgery: Indications include epidermal nevi, actinic cheilitis, keloids, verrucae, skin tags, anal tags, keratoses, scar revision, debulking benign tumors, and decubitis ulcers. It is also used for laser assisted site preparation for hair transplantation. The JOULE 2940 nm Multi-Platform Systems with ProFractional handpiece and delivery system is intended for use in dermatological procedures requiring skin resurfacing, and ablation and coagulation of soft tissue. BBL (300-1400nm) Indications for Use: The JOULE Multi-Platform Systems and Accessories are indicated for use in surgical, aesthetic and cosmetic applications requiring selective photothermolysis (photocoagulation or coagulation) and hemostasis of soft tissue in the medical specialties of general and plastic surgery and dermatology. It is intended for use for: • Mild to moderate inflammatory and pustular inflammatory acne vulgaris. (420nm BP filter, 515nm LP filter, 560 LP filter) • The treatment of benign pigmented lesions including dyschromia, hyperpigmentation, melasma, ephelides (freckles) (515nm LP filter, 560nm LP filter) • The treatment of cutaneous lesions including warts, scars and striae; (515nm LP filter, 560nm LP filter) • The treatment of benign cutaneous vascular lesions, including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations; (560nm LP filter, 590nm LP filter) • The removal of unwanted hair from all skin types, and to effect stable long-term, or permanent, hair reduction (590nm LP filter, 640nm LP filter, 695 LP filter) • Topical heating for the purpose of elevating tissue temperature for the temporary relief of minor muscle and joint pain and stiffness, the temporary relief of minor joint pain associated with arthritis, the temporary increase in local circulation where applied, and the relaxation of muscles. In addition, it may also help muscle spasms, minor sprains and strains, and minor muscular back pain. (800 nm LP Filter) […]
Excerpt — verbatim from the FDA 510(k) summary, retrieved 7 Oct 2026; "[…]" marks text omitted from the source.
Page updated: October 7, 2026 · How we verify
New-equipment price not yet documented
For a complete budget, ask for an itemized quote covering the device, accessories, training and service.
Price sourcesSources, dates and configurations
No price sources are documented yet. Ask the seller for a current, itemized quote.
Key factsCompany, specifications and verification dates
| Manufacturer | Sciton |
|---|---|
| Company | Owner: Employee-owned (co-founders James Hobart and Daniel Negus) (family / founder owned, since 1997) · Distribution: direct |
| Parent company | Sciton |
| Brand owner | Sciton |
| Built by (OEM) | Sciton Inc. |
| Category | Er:YAG Resurfacing |
| Technology | Er:YAG 2940nm tunable full-field |
| FDA status | FDA record cited — see scope |
| 510(k) citation | K101916 |
| New price range | Not published |
| Used price reference | Not published |
| Consumables | Not published |
| Launch year | 2007 |
| Pricing | Not published |
| Manufacturer-source documents checked | Not published |
Overview
Contour TRL is Sciton’s 2940 nm Er:YAG resurfacing technology with independently adjustable ablation and coagulation. It provides full-field treatment, distinct from fractional delivery.
Confirm console compatibility and the installed scanner with Sciton; a modular platform name alone does not establish that Contour TRL is included. Sciton announced the new Contour TRL on August 7, 2007, with availability planned for that fall.
This is the technology introduction, not the release date of every compatible console.
FDA & regulatory detailClearance timeline, authorization route and citation notes
Source and verification notes
·FDA database · Updated Oct 7, 2026K101916 covers JOULE with multiple wavelength-specific applications. Its 2940 nm section includes resurfacing and wrinkles and separately describes ProFractional delivery. It does not by itself establish that every JOULE or mJOULE includes the marketed Contour TRL module. Confirm console and scanner compatibility. Additional sources: . Only the stated fields were reviewed; not whole-profile verification.K101916 covers JOULE with multiple wavelength-specific applications. Its 2940 nm section includes resurfacing and wrinkles and separately describes ProFractional delivery. It does not by itself establish that every JOULE or mJOULE includes the marketed Contour TRL module. Confirm console and scanner compatibility.
FDA-cleared indications (verbatim)
K101916 (Sciton, Inc, 2011)
The 755 nm Alexandrite system is designed for use in: The ClearScan ALX 755nm Alexandrite laser system with its accessories is indicated for stable long-term, or permanent hair reduction for all skin types (Fitzpatrick I - VI) including tanned skin. It is also indicated for the treatment of vascular lesions, benign pigmented lesions and wrinkles. Q-Switched 755 nm Alexandrite Indications for Use: The JOULE Q-Switched 755 nm Alex Multi-Platform Systems with accessories are indicated for the following uses: Pigmented Lesions Tattoos The 1064 nm Nd:YAG Indications for Use: Coagulation and hemostasis of benign vascular lesions such as, but not limited to, telangiectasias and rosacea. Removal of unwanted hair (for stable, long term or permanent hair reduction) through selective targeting of melanin in hair follicles and for the treatment of Pseudofolliculitis Barbae (PFB). Treatment of facial wrinkles. The JOULE 1064 nm Nd:YAG with fiber delivery is indicated for laser assisted lipolysis. […] 2940 nm Indications for Use: The JOULE 2940 nm Multi-Platform Systems with delivery accessories are designed for use in surgical applications requiring the excision, incision, ablation, vaporization, and coagulation of soft tissue, and for skin resurfacing. Aesthetic Surgery: Skin resurfacing and treatment of wrinkles. Dermatology & Plastic Surgery: Indications include epidermal nevi, actinic cheilitis, keloids, verrucae, skin tags, anal tags, keratoses, scar revision, debulking benign tumors, and decubitis ulcers. It is also used for laser assisted site preparation for hair transplantation. The JOULE 2940 nm Multi-Platform Systems with ProFractional handpiece and delivery system is intended for use in dermatological procedures requiring skin resurfacing, and ablation and coagulation of soft tissue. BBL (300-1400nm) Indications for Use: The JOULE Multi-Platform Systems and Accessories are indicated for use in surgical, aesthetic and cosmetic applications requiring selective photothermolysis (photocoagulation or coagulation) and hemostasis of soft tissue in the medical specialties of general and plastic surgery and dermatology. It is intended for use for: • Mild to moderate inflammatory and pustular inflammatory acne vulgaris. (420nm BP filter, 515nm LP filter, 560 LP filter) • The treatment of benign pigmented lesions including dyschromia, hyperpigmentation, melasma, ephelides (freckles) (515nm LP filter, 560nm LP filter) • The treatment of cutaneous lesions including warts, scars and striae; (515nm LP filter, 560nm LP filter) • The treatment of benign cutaneous vascular lesions, including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations; (560nm LP filter, 590nm LP filter) • The removal of unwanted hair from all skin types, and to effect stable long-term, or permanent, hair reduction (590nm LP filter, 640nm LP filter, 695 LP filter) • Topical heating for the purpose of elevating tissue temperature for the temporary relief of minor muscle and joint pain and stiffness, the temporary relief of minor joint pain associated with arthritis, the temporary increase in local circulation where applied, and the relaxation of muscles. In addition, it may also help muscle spasms, minor sprains and strains, and minor muscular back pain. (800 nm LP Filter) […]
Excerpt — verbatim from the FDA 510(k) summary, retrieved 7 Oct 2026; "[…]" marks text omitted from the source.
Marketed for
Erbium — Er:YAG 2940nm tunable full-field
Marketing claims are the manufacturer's own and are not the same as a cleared indication.
Parent company: Sciton
Legal manufacturer: Sciton Inc. (United States)
Applicant on the FDA record
Sciton, IncThe applicant named on the FDA record can differ from the brand shown on the device.
Regulatory data comes from public FDA records and may lag recent updates. Confirm the applicable status and documentation before purchase.
Treatment & running costs
Treatment and running-cost details aren’t documented yet.
Ask the supplier for the session schedule, supplies per treatment and annual service costs.
Use your own figures in the calculatorPayback calculatorEnter your quote, volume and running costs
Estimate your payback
Enter your quote and treatment costs for Sciton Contour TRL (Joule/mJoule module). Published figures appear where available; review them before using the estimate.
No verified per-treatment supply cost is on file. Enter your own allowance. Use $0 only if you have confirmed that it applies to your practice.
New price not published — enter the number on your quote.
20 is an illustrative default — change it to your volume.
No sourced per-session price on file — enter what you charge.
Required — enter your cost; missing data does not mean $0.
Required — include staff time and your own time. Enter 0 only to explicitly exclude labor from this estimate.
Annual service contract ÷ 12, if you carry one.
Your estimate
Enter purchase price, price you charge per treatment, consumable cost per treatment, labor cost per treatment to see contribution and a payback range.
This model ignores financing — if you lease or borrow, add your monthly payment. Estimates from your inputs and our published ranges — not a projection, guarantee or financial advice. How we calculate this.
Warranty & serviceWhat to confirm in writing before you buy
Before buying new or used, confirm in writing:
- Current warranty coverage
- Included training
- Service terms
Chains using this device
A chain listing does not establish availability at every location.
No confirmed chain deployments recorded yet.
Owner & operator reviews
Write a reviewNo owner or operator reviews yet. Be the first →
Current alternatives
Current catalog models to research. Confirm availability and configuration with the supplier.
History7 tracked changes
Every tracked change to pricing, lifecycle status, FDA data and warranty terms — newest first.
October 7, 2026
Manufacturer documentation and chronology 2026-10-07
Sciton announcement dated August 7, 2007 distinguishes new Contour TRL from the earlier Contour dual-pulse laser and says availability was planned for fall 2007. Corrected the technology introduction year from 2004 to 2007; exact console compatibility remains unresolved. Historical manufacturer documentation, not a current sales offer. No equipment price, regulatory status or whole-profile verification date changed.
Source: https://sciton.com/scitons-introduces-new-contour-tunable-resurfacing-laser-trl/
October 7, 2026
FDA indication
Source: Catalog update
October 7, 2026
FDA source URL
https://www.accessdata.fda.gov/cdrh_docs/pdf10/K101916.pdf
Source: Catalog update
October 7, 2026
Batch 04 primary-source corrections
Reviewed changed fields only on October 7, 2026. Unchanged equipment prices and other fields are not reverified. Scope, generation, region and offer terms remain specific to each source.
Source: https://www.accessdata.fda.gov/cdrh_docs/pdf10/K101916.pdf
October 7, 2026
fda status batch 04 primary-source evidence
Claim-specific evidence; not a whole-profile verification.
Source: https://www.accessdata.fda.gov/cdrh_docs/pdf10/K101916.pdf
October 6, 2026
Source-based profile correction
Official-source review on October 6, 2026 of the listed fields only. Pricing, regulatory records and current sales availability are not independently verified by this edit.
Source: https://sciton.com/wp-content/uploads/2022/04/2600-029-08-Rev-F-ResurfacingPerfected-Product-Brochure-1.pdf
August 1, 2026
Record created
Added to The Aesthetic Index — August 2026
Source: The Aesthetic Index editorial
Cite this data: The Aesthetic Index, "Sciton Contour TRL (Joule/mJoule module) — pricing, FDA status and cost to own", aestheticindex.co (accessed November 23, 2026).
Get the full State of Aesthetic Devices 2026 report
A catalog of US-marketed aesthetic and wellness devices — preview it free.
Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.