Hoya ConBio MedLite C6
Q-Switched Tattoo/Pigment · QS Nd:YAG 532/1064nm
Technology: Nd:YAG Laser
Classification & configurations
Category group: Resurfacing & pigment (ablative, fractional, picosecond, vascular)
At a glance
- New-unit reference · older model
- Not published
- Used asking price
- $10k–$20kSource not documented
- FDA status
Record scope: The original K014234 summary and indications page explicitly name Medlite C6 Q-Switched Nd:YAG Laser. K060977 is a later accessory submission and cites the C6/standard MultiSpot handpiece under K014234. The January 2002 clearance is not proof of the commercial launch date; the two records have distinct scopes.
- Supplies & recurring costs
- See supply and replacement costs below.
Sources and data on file
Data on file
- Recurring consumables
- Not verified
- Used asking prices
- Not verified
- This panel shows a per-treatment supply cost only when a recorded figure has a dated source.
- Bottle prices and estimates may still appear under Treatment & running costs.
- The calculator may include a labeled planning estimate. Review it or enter your own allowance; missing data never means $0.
Figures are reference points, not current offers. Used asking prices are not completed-sale values.
Read FDA-cleared indicationsExact wording from 1 FDA record
K060977 (Hoya Conbio, Inc., 2006)
HOYA ConBio Compression Tool and Handpiece Accessories for use with the MedLite™ C Series Q-Switched Nd:YAG Laser Systems — Indications for Use: Tattoo Removal; Nevus of Ota; Hair Removal; Vascular Lesions; Dermal Pigmented Lesions; Epidermal Pigmented Lesions; Laser Resurfacing for Acne scars and wrinkles; Incision, Excision, Ablation, Vaporization of Soft Tissue for General Dermatology
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
Page updated: October 6, 2026 · How we verify
Older-model price not documented
Use the ownership information below and compare current models.
Axis runs $0–$20k. Reference figures, not current offers. Used asking prices are not completed-sale values.
Not verified
We hold no per-treatment consumable price for this device from a dated source. Ask the seller for a written per-treatment cost.
Price sourcesSources, dates and configurations
Key factsCompany, specifications and verification dates
| Manufacturer | Hoya ConBio |
|---|---|
| Company | Not published |
| Parent company | Cynosure Lutronic |
| Brand owner | Hoya ConBio |
| Built by (OEM) | Hoya ConBio |
| Category | Q-Switched Tattoo/Pigment |
| Technology | QS Nd:YAG 532/1064nm |
| FDA status | FDA record cited — see scope |
| 510(k) citation | K014234, K060977 |
| New-unit reference (older model) | Not published |
| Used price reference | $10k–$20k |
| Consumables | Not published |
| Launch year | 2006 |
| Pricing | Not published |
| Manufacturer-source documents checked | Not published |
Overview
MedLite C6 is a legacy Q-switched Nd:YAG laser. K014234 is the January 2002 system record; K060977 covers later compression-tool and handpiece accessories.
Confirm the serial number, functioning handpieces, maintenance history and applicable labeling before buying a used unit.
How it worksTechnology and manufacturing
How the technology works
MedLite C6 is a Q-switched Nd:YAG laser with standard 1064 nm and frequency-doubled 532 nm output. Optional dye handpieces provide 585 nm or 650 nm.
Available wavelengths depend on the installed, functioning handpieces; no fixed session interval or comparative performance claim is established here.
Patented technology
The ConBio dye-conversion handpiece system (585/650nm) and homogenized flat-top beam optics; the C6 predates PTP, which ConBio reserved for the RevLite line.
Origin
Fremont, California, USA (ConBio/HOYA ConBio).
FDA & regulatory detailClearance timeline, authorization route and citation notes
Source and verification notes
·FDA database · Updated Oct 6, 2026Changed-field review, not complete profile verification. The original K014234 summary and indications page explicitly name Medlite C6 Q-Switched Nd:YAG Laser. K060977 is a later accessory submission and cites the C6/standard MultiSpot handpiece under K014234. The January 2002 clearance is not proof of the commercial launch date; the two records have distinct scopes.The original K014234 summary and indications page explicitly name Medlite C6 Q-Switched Nd:YAG Laser. K060977 is a later accessory submission and cites the C6/standard MultiSpot handpiece under K014234. The January 2002 clearance is not proof of the commercial launch date; the two records have distinct scopes.
FDA-cleared indications (verbatim)
K060977 (Hoya Conbio, Inc., 2006)
HOYA ConBio Compression Tool and Handpiece Accessories for use with the MedLite™ C Series Q-Switched Nd:YAG Laser Systems — Indications for Use: Tattoo Removal; Nevus of Ota; Hair Removal; Vascular Lesions; Dermal Pigmented Lesions; Epidermal Pigmented Lesions; Laser Resurfacing for Acne scars and wrinkles; Incision, Excision, Ablation, Vaporization of Soft Tissue for General Dermatology
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
Marketed for
Nd:YAG — QS Nd:YAG 532/1064nm
Marketing claims are the manufacturer's own and are not the same as a cleared indication.
Parent company: Cynosure Lutronic
Legal manufacturer: Hoya ConBio (United States)
Applicant on the FDA record
Hoya Conbio, Inc.The applicant named on the FDA record can differ from the brand shown on the device.
Regulatory data comes from public FDA records and may lag recent updates. Confirm the applicable status and documentation before purchase.
Treatment & running costs
Supplies & recurring costs
The Hoya ConBio operation manual identifies replaceable protective windows and optional dye barrels. It lists minimum dye lifetimes of 20,000 pulses at 585 nm and 10,000 at 650 nm, with replacement when useful energy is no longer obtained.
It recommends annual flashlamp shot-count checks and replacement at 50 million shots. These are historical manual specifications; obtain current parts prices and service terms for the offered unit.
Source notes
Changed-field review, not complete profile verification. The Hoya ConBio operation manual identifies replaceable protective windows and optional dye barrels.
It lists minimum dye lifetimes of 20,000 pulses at 585 nm and 10,000 at 650 nm, with replacement when useful energy is no longer obtained. It recommends annual flashlamp shot-count checks and replacement at 50 million shots.
These are historical manual specifications; obtain current parts prices and service terms for the offered unit.
Not yet documented: session schedule, treatment pricing, annual service costs.
Payback calculatorEnter your quote, volume and running costs
Estimate your payback
Enter your quote and treatment costs for Hoya ConBio MedLite C6. Published figures appear where available; review them before using the estimate.
Start from
No verified per-treatment supply cost is on file. Enter your own allowance. Use $0 only if you have confirmed that it applies to your practice.
Pre-filled from the midpoint of the published used asking range
20 is an illustrative default — change it to your volume.
No sourced per-session price on file — enter what you charge.
Required — enter your cost; missing data does not mean $0.
Required — include staff time and your own time. Enter 0 only to explicitly exclude labor from this estimate.
Annual service contract ÷ 12, if you carry one.
Your estimate
Enter price you charge per treatment, consumable cost per treatment, labor cost per treatment to see contribution and a payback range.
This model ignores financing — if you lease or borrow, add your monthly payment. Estimates from your inputs and our published ranges — not a projection, guarantee or financial advice. How we calculate this.
Screening considerationsCatalog notes to check against the current instructions for use
Catalog screening notes
Gold salts history, recent tanning or melasma-prone skin at 532nm, isotretinoin per protocol, keloid history, oxidizing cosmetic tattoos. On Fitzpatrick V-VI stay at 1064nm and test-spot — the C6 has no PTP safety valve for low-fluence work.
These notes are not a complete or verified manufacturer contraindication list. Use the current instructions for the exact device and applicator to determine contraindications, warnings and patient eligibility.
Warranty & serviceWhat to confirm in writing before you buy
Before buying new or used, confirm in writing:
- Current warranty coverage
- Included training
- Service terms
Chains using this device
A chain listing does not establish availability at every location.
No confirmed chain deployments recorded yet.
Owner & operator reviews
Write a reviewNo owner or operator reviews yet. Be the first →
Current alternatives
Current catalog models to research. Confirm availability and configuration with the supplier.
History11 tracked changes
Every tracked change to pricing, lifecycle status, FDA data and warranty terms — newest first.
October 6, 2026
Council batch 01 final review corrections
Reviewed changed fields only on October 6, 2026. Unchanged equipment prices and other fields are not reverified. Source regions and model generations must not be generalized. Additional sources: https://acmerevival.com/wp-content/uploads/2022/09/Cynosure_Hoya_ConBio_MedLite_C6_Laser_System_manual.pdf ; https://www.accessdata.fda.gov/cdrh_docs/pdf6/K060977.pdf
Source: https://www.accessdata.fda.gov/cdrh_docs/pdf/k014234.pdf
October 6, 2026
FDA K-numbers
K060977 → K014234; K060977
Source: Catalog update
October 6, 2026
FDA indication
Source: Catalog update
October 6, 2026
FDA source URL
https://www.accessdata.fda.gov/cdrh_docs/pdf/k014234.pdf
Source: Catalog update
October 6, 2026
consumables cost council batch 01 final review evidence
Claim-specific evidence; not a whole-profile verification.
Source: https://acmerevival.com/wp-content/uploads/2022/09/Cynosure_Hoya_ConBio_MedLite_C6_Laser_System_manual.pdf
October 6, 2026
fda status council batch 01 final review evidence
Claim-specific evidence; not a whole-profile verification.
Source: https://www.accessdata.fda.gov/cdrh_docs/pdf/k014234.pdf
October 1, 2026
MedLite accessory citation scope
Added the remaining blank public overview and clarified the cited accessory record versus the underlying laser system. Other profile fields have not received full factual signoff.
Source: https://www.accessdata.fda.gov/cdrh_docs/pdf6/K060977.pdf
September 4, 2026
consumables detail
Manufacturer-conduct language removed or restated as a dated, sourced fact.
Source: Editorial sweep 2026-09-04: manufacturer-conduct language neutralized
September 4, 2026
notes
Ubiquitous used tattoo workhorse → removed
Unsourced evaluative sentence removed under the opinion-layer gate.
Source: Catalog update — Wave D opinion-layer gate, 2026-09-04
August 5, 2026
Warranty & service
Source: Catalog update
August 1, 2026
Record created
Added to The Aesthetic Index — August 2026
Source: The Aesthetic Index editorial
Cite this data: The Aesthetic Index, "Hoya ConBio MedLite C6 — pricing, FDA status and cost to own", aestheticindex.co (accessed November 23, 2026).
Get the full State of Aesthetic Devices 2026 report
A catalog of US-marketed aesthetic and wellness devices — preview it free.
Explore this model’s specs and owner reviews. For new-equipment inquiries, browse current models.
Browse current modelsDevice and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.