Skip to content

Allergan Aesthetics CoolSculpting (Legacy/Gen 1-2)

Cryolipolysis · Cryolipolysis fat freezing

Technology: Cryolipolysis

Legacy model

At a glance

New-unit reference · older model
$100k–$150kSource not documented
Used asking price
$15k–$45kSource not documented
FDA status

Record scope: DEN090002 links to K080521 for the de novo classification. K080118 and K090094 describe earlier cooling/thermal-therapy systems; they do not independently establish the later fat-reduction indication. K120023 covers abdomen and flanks subject to its labeling. Confirm the exact legacy console and applicators rather than extending this history to every later treatment area. Reviewed 7 Oct 2026.

Supplies & recurring costs
Cycle cards plus applicator liners and gel pads. Current manufacturer cycle-card pricing has not been verified here.
View supply details
Sources and data on file

Data on file

Recurring consumables
Not verified
FDA
FDA record cited — see scopeDe Novo: DEN090002, K080521, K120023, K080118, K090094
Used asking prices
Not verified
  • This panel shows a per-treatment supply cost only when a recorded figure has a dated source.
  • Bottle prices and estimates may still appear under Treatment & running costs.
  • The calculator may include a labeled planning estimate. Review it or enter your own allowance; missing data never means $0.

Figures are reference points, not current offers. Used asking prices are not completed-sale values.

·FDA database · Updated Oct 7, 2026
Read FDA-cleared indicationsExact wording from 3 FDA records

K120023 (Zeltiq Aesthetics, Inc., 2012)

The CoolSculpting System is a skin cooling or heating device. The device is indicated for cold-assisted lipolysis of the abdomen, as well as the flank, or "love handles" in individuals with a Body Mass Index (BMI) of 30 or less. The device is intended to affect the appearance of the abdomen and the flank. Cooling with the device may also be used to minimize pain and thermal injury during laser and dermatological treatments and act as a local anesthetic for procedures that induce minor local discomfort. The CoolSculpting System is also indicated for use to provide localized thermal therapy (hot or cold) to minimize pain post-trauma and post-surgery, and for temporary relief of minor aches, pains, and muscle spasms. The optional massage function can also be used for the temporary relief of minor muscle aches, pain, and spasm, for temporary improvement in local circulation and temporary reduction in the appearance of cellulite. The ZELTIQ Gelpad facilitates thermal contact of the device with a patient's skin by mitigating minor variances in device-to-skin contact.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K080118 (Zeltiq Aesthetics, 2008)

The Zeltiq CLN1 Dermal Cooling Device is intended for use as a skin cooling device to minimize pain and thermal injury during laser and dermatological treatments. Alternative uses include skin cooling as a local anesthetic for procedures that induce minor local discomfort. The Zeltiq CLN1 Dermal Cooling Device can also provide localized thermal therapy (hot or cold) to minimize pain for post traumatic and/or post surgical pain and to temporarily relieve minor aches and pains and muscle spasms. The optional massage function can also be used for the temporary relief of minor muscle aches, pain, and spasm, for temporary improvement in local circulation and temporary reduction in the appearance of cellulite. The Zeltiq Coupling Gels facilitate thermal contact of the Zeltiq CLN1 Dermal Cooling Device with a patient's skin by mitigating minor variances in device-to-skin contact.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K090094 (Zeltiq Aesthetics, 2009)

The Zeltiq System is intended for use as a skin cooling device to minimize pain and thermal injury during laser and dermatological treatments. Alternative uses include skin cooling as a local anesthetic for procedures that induce minor local discomfort. The Zeltiq System can also provide localized thermal therapy (hot or cold) to minimize pain for post traumatic and/or post surgical pain and to temporarily relieve minor aches and pains and muscle spasms. The optional massage function can also be used for the temporary relief of minor muscle aches, pain, and spasm, for temporary improvement in local circulation and temporary reduction in the appearance of cellulite. Zeltiq Gel facilitates thermal contact of the Zeltiq System with a patient's skin by mitigating minor variances in device-to-skin contact.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

Page updated: October 7, 2026 · How we verify

Older-model price references
New-unit reference$100k–$150k
Source not documented
Used$15k–$45k
Source not documented

Axis runs $0–$150k. Reference figures, not current offers. Used asking prices are not completed-sale values.

Consumable cost per treatment

Not verified

We hold no per-treatment consumable price for this device from a dated source. Ask the seller for a written per-treatment cost.

Price sourcesSources, dates and configurations
New-unit reference (older model): $100k–$150k·Researched estimate — no dated source on file yet; not a quote.
Used price reference: $15k–$45k·Researched estimate — no dated source on file yet; not a quote.
Key factsCompany, specifications and verification dates
Key facts
ManufacturerAllergan Aesthetics (AbbVie)
CompanyOwner: AbbVie Inc. (NYSE: ABBV) (subsidiary, since 2020) · Distribution: direct
Parent companyAbbVie / Allergan Aesthetics
Brand ownerAllergan Aesthetics
Built by (OEM)Zeltiq Aesthetics Inc.
CategoryBody Contouring
TechnologyCryolipolysis fat freezing
FDA statusFDA record cited — see scope
510(k) citationDe Novo: DEN090002, K080521, K120023, K080118, K090094
New-unit reference (older model)$100k–$150k
Used price reference$15k–$45k
ConsumablesCycle cards plus applicator liners and gel pads. Current manufacturer cycle-card pricing has not been verified here.
Launch year2010
PricingNot published
Manufacturer-source documents checkedNot published

Company source

·Manufacturer-provided · Updated Oct 7, 2026K120023 scanned summary pages 1–2 inspected: thermoelectric cooling/heating and optional massage. FDA DEN090002 identifies K080521; earlier K080118 names CLN1 and K090094 names Zeltiq System, so both earlier identifiers are retained. Added missing de novo-linked identifier, without treating the earlier cooling indications as fat-reduction authorization. De novo source: FDA record .

Overview

This entry covers legacy CoolSculpting systems, rather than one precisely identified console and applicator package. The FDA record describes controlled thermoelectric cooling and heating, with optional massage and coupling gel to maintain skin contact.

Treatment-area eligibility depends on the applicable labeling. When comparing equipment, identify the console generation, installed applicators and required supplies; later configurations should not be assumed on an older unit.

How it worksTechnology and manufacturing

How the technology works

CoolSculpting uses controlled cooling to reduce localized subcutaneous fat. Applicator design, treatment duration and eligible body areas vary by system generation and labeling.

The manufacturer reports up to 20–25% fat-layer reduction from a small clinical study, not a guaranteed result for every treatment. Results vary, and the procedure is not a treatment for weight loss.

Later Elite treatment examples should not be assumed to describe every legacy system.

Patented technology

The Zeltiq cryolipolysis patent estate — licensed from the Mass General work of Anderson and Manstein — covering selective cold-induced adipocyte apoptosis, plus Freeze Detect skin-protection sensing and the vacuum applicator geometry.

Origin

Zeltiq Aesthetics, Pleasanton, California (Allergan/AbbVie after 2017).

FDA & regulatory detailClearance timeline, authorization route and citation notes

Source and verification notes

·FDA database · Updated Oct 7, 2026K120023 scanned summary pages 1–2 inspected: thermoelectric cooling/heating and optional massage. FDA DEN090002 identifies K080521; earlier K080118 names CLN1 and K090094 names Zeltiq System, so both earlier identifiers are retained. Added missing de novo-linked identifier, without treating the earlier cooling indications as fat-reduction authorization. De novo source: FDA record .
Authorized via 510(k)

DEN090002 links to K080521 for the de novo classification. K080118 and K090094 describe earlier cooling/thermal-therapy systems; they do not independently establish the later fat-reduction indication. K120023 covers abdomen and flanks subject to its labeling. Confirm the exact legacy console and applicators rather than extending this history to every later treatment area. Reviewed 7 Oct 2026.

FDA-cleared indications (verbatim)

K120023 (Zeltiq Aesthetics, Inc., 2012)

The CoolSculpting System is a skin cooling or heating device. The device is indicated for cold-assisted lipolysis of the abdomen, as well as the flank, or "love handles" in individuals with a Body Mass Index (BMI) of 30 or less. The device is intended to affect the appearance of the abdomen and the flank. Cooling with the device may also be used to minimize pain and thermal injury during laser and dermatological treatments and act as a local anesthetic for procedures that induce minor local discomfort. The CoolSculpting System is also indicated for use to provide localized thermal therapy (hot or cold) to minimize pain post-trauma and post-surgery, and for temporary relief of minor aches, pains, and muscle spasms. The optional massage function can also be used for the temporary relief of minor muscle aches, pain, and spasm, for temporary improvement in local circulation and temporary reduction in the appearance of cellulite. The ZELTIQ Gelpad facilitates thermal contact of the device with a patient's skin by mitigating minor variances in device-to-skin contact.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K080118 (Zeltiq Aesthetics, 2008)

The Zeltiq CLN1 Dermal Cooling Device is intended for use as a skin cooling device to minimize pain and thermal injury during laser and dermatological treatments. Alternative uses include skin cooling as a local anesthetic for procedures that induce minor local discomfort. The Zeltiq CLN1 Dermal Cooling Device can also provide localized thermal therapy (hot or cold) to minimize pain for post traumatic and/or post surgical pain and to temporarily relieve minor aches and pains and muscle spasms. The optional massage function can also be used for the temporary relief of minor muscle aches, pain, and spasm, for temporary improvement in local circulation and temporary reduction in the appearance of cellulite. The Zeltiq Coupling Gels facilitate thermal contact of the Zeltiq CLN1 Dermal Cooling Device with a patient's skin by mitigating minor variances in device-to-skin contact.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K090094 (Zeltiq Aesthetics, 2009)

The Zeltiq System is intended for use as a skin cooling device to minimize pain and thermal injury during laser and dermatological treatments. Alternative uses include skin cooling as a local anesthetic for procedures that induce minor local discomfort. The Zeltiq System can also provide localized thermal therapy (hot or cold) to minimize pain for post traumatic and/or post surgical pain and to temporarily relieve minor aches and pains and muscle spasms. The optional massage function can also be used for the temporary relief of minor muscle aches, pain, and spasm, for temporary improvement in local circulation and temporary reduction in the appearance of cellulite. Zeltiq Gel facilitates thermal contact of the Zeltiq System with a patient's skin by mitigating minor variances in device-to-skin contact.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

Marketed for

Cryolipolysis — Cryolipolysis fat freezing

Marketing claims are the manufacturer's own and are not the same as a cleared indication.

Parent company: AbbVie / Allergan Aesthetics

Legal manufacturer: Zeltiq Aesthetics Inc. (United States)

Applicant on the FDA record

ZELTIQ Aesthetics, Inc.The applicant named on the FDA record can differ from the brand shown on the device.

Regulatory data comes from public FDA records and may lag recent updates. Confirm the applicable status and documentation before purchase.

Look-alike devices

Comparing an unbranded cryolipolysis unit? Check the exact model rather than relying on similar photos or treatment claims.

Listed manufacturer for this profile: Zeltiq Aesthetics Inc.

  • FDA record: Match any claimed 510(k) or De Novo number to the exact model and applicant in the FDA database.
  • Support: Get written warranty, training, consumables and service terms from the seller.
  • Financing: Confirm availability for the exact unit before including it in your budget.

We do not profile these unbranded units or verify their support and financing terms. Any FDA record cited here must be read for its exact model and scope; it does not automatically cover similar-looking units.

What we publish about legal and safety matters

Treatment & running costs

Supplies & recurring costs

Cycle cards plus applicator liners and gel pads. Current manufacturer cycle-card pricing has not been verified here, and the reseller card figures previously shown carried no dated primary source.

  • Vendor restrictions: usage-metered — treatment credits, pulses or usage charges apply
·Dealer quote · Updated Aug 30, 2026
Source notes

Cosmetic Laser Exchange and MNML Aesthetics card/liner listings; per-cycle figures derived from card price and cycle count on the same listing. 30 Aug 2026 research pass.

Additional supply notes

Cycle cards plus applicator liners and gel pads. Current manufacturer cycle-card pricing has not been verified here.

Not yet documented: session schedule, treatment pricing, annual service costs.

Payback calculatorEnter your quote, volume and running costs

Estimate your payback

Enter your quote and treatment costs for Allergan Aesthetics CoolSculpting (Legacy/Gen 1-2). Published figures appear where available; review them before using the estimate.

Start from

No verified per-treatment supply cost is on file. Enter your own allowance. Use $0 only if you have confirmed that it applies to your practice.

Pre-filled from the midpoint of the published new-price range

20 is an illustrative default — change it to your volume.

No sourced per-session price on file — enter what you charge.

Required — enter your cost; missing data does not mean $0.

Required — include staff time and your own time. Enter 0 only to explicitly exclude labor from this estimate.

Annual service contract ÷ 12, if you carry one.

Your estimate

Enter price you charge per treatment, consumable cost per treatment, labor cost per treatment to see contribution and a payback range.

This model ignores financing — if you lease or borrow, add your monthly payment. Estimates from your inputs and our published ranges — not a projection, guarantee or financial advice. How we calculate this.

Screening considerationsCatalog notes to check against the current instructions for use

Catalog screening notes

Cryoglobulinemia, cold agglutinin disease, paroxysmal cold hemoglobinuria (absolute); hernia in the treatment zone, pregnancy, impaired sensation. Counsel every patient on paradoxical adipose hyperplasia, a known rare adverse event described in the device labeling.

These notes are not a complete or verified manufacturer contraindication list. Use the current instructions for the exact device and applicator to determine contraindications, warnings and patient eligibility.

Warranty & serviceWhat to confirm in writing before you buy

Before buying new or used, confirm in writing:

  • Current warranty coverage
  • Included training
  • Service terms

Chains using this device

A chain listing does not establish availability at every location.

  • SKINNEY Medspa

    Medspa

    Company site

    Confirmed

Owner & operator reviews

Write a review

No owner or operator reviews yet. Be the first →

Current alternatives

Current catalog models to research. Confirm availability and configuration with the supplier.

Allergan Aesthetics CoolSculpting Elite

Cryolipolysis

New-equipment price not yet documented.

Classys Clatuu Alpha

Cryolipolysis

New-equipment price not yet documented.

Research comparisons

Includes current and older models.

History18 tracked changes

Every tracked change to pricing, lifecycle status, FDA data and warranty terms — newest first.

  1. October 7, 2026

    Recovery and legacy scope 2026-10-07

    K120023 scanned summary pages 1–2 inspected: thermoelectric cooling/heating and optional massage. FDA DEN090002 identifies K080521; earlier K080118 names CLN1 and K090094 names Zeltiq System, so both earlier identifiers are retained. Added missing de novo-linked identifier, without treating the earlier cooling indications as fat-reduction authorization. De novo source: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/denovo.cfm?ID=DEN090002 .

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf12/K120023.pdf

  2. October 7, 2026

    FDA K-numbers

    DEN090002; K120023; K080118; K090094 → DEN090002; K080521; K120023; K080118; K090094

    Source: Catalog update

  3. October 7, 2026

    Catalog evidence limits 2026-10-07

    Editorial evidence-limit correction: distinguish information not verified in this catalog from a claim that it is unavailable anywhere. Remove unsupported market rankings, blanket safety, comparative costs or return assumptions where present. Equipment price fields, source observation dates and whole-profile verification dates are unchanged. This is not new complete-profile or commercial-price verification.

    Source: https://aestheticindex.co/methodology

  4. October 7, 2026

    FDA reviewed transcription status 2026-10-07 K090094

    Indications form visually verified in PR353. Mark as manual to preserve exact source endings without invented punctuation and protect against automated re-extraction.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf9/K090094.pdf

  5. October 7, 2026

    FDA reviewed transcription status 2026-10-07 K080118

    Indications form visually verified in PR353. Mark as manual to preserve exact source endings without invented punctuation and protect against automated re-extraction.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf8/K080118.pdf

  6. October 7, 2026

    FDA excerpt boundaries 2026-10-07 K090094

    Visually checked the Indications for Use form on PDF page(s) 5 on 2026-10-07. Transcription retains indication limits and wavelength/accessory headings; excludes adjacent technical/comparison sections. Whitespace and typography normalized. Source spelling retained. This excerpt correction does not reverify commercial-model applicability.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf9/K090094.pdf

  7. October 7, 2026

    FDA excerpt boundaries 2026-10-07 K080118

    Visually checked the Indications for Use form on PDF page(s) 5 on 2026-10-07. Transcription retains indication limits and wavelength/accessory headings; excludes adjacent technical/comparison sections. Whitespace and typography normalized. Source spelling retained. This excerpt correction does not reverify commercial-model applicability.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf8/K080118.pdf

  8. October 7, 2026

    Batch 03 reconciled field corrections

    Visually read the signed indication enclosure on page 5. Replaces generic family prose with the documented 2012 scope; no later treatment sites or current recall status inferred. Additional sources: . Equipment price ranges and whole-profile verification dates preserved.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf12/K120023.pdf

  9. October 7, 2026

    FDA indication

    Source: Catalog update

  10. October 7, 2026

    FDA source URL

    https://www.accessdata.fda.gov/cdrh_docs/pdf12/K120023.pdf

    Source: Catalog update

  11. October 7, 2026

    Batch 03 reconciled source evidence

    Preserve earlier evidence in history; changed fields only, not whole-profile verification.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf12/K120023.pdf

  12. October 6, 2026

    Batch 03 primary-source corrections

    Reviewed changed fields only on October 6, 2026. Unchanged equipment prices and other fields are not reverified. Scope, generation, region and offer terms remain specific to each source.

    Source: https://www.coolsculpting.com/

  13. September 7, 2026

    patented tech

    Source: Catalog update — editorial sentences removed (neutral-voice standard, 7 Sep 2026)

  14. September 4, 2026

    contraindications

    Manufacturer-conduct language removed or restated as a dated, sourced fact.

    Source: Editorial sweep 2026-09-04: manufacturer-conduct language neutralized

  15. August 30, 2026

    FDA K-numbers

    Source: Catalog update

  16. August 9, 2026

    FDA K-numbers

    Source: Catalog update

  17. August 5, 2026

    Warranty & service

    Source: Catalog update

  18. August 1, 2026

    Record created

    Added to The Aesthetic Index — August 2026

    Source: The Aesthetic Index editorial

Cite this data: The Aesthetic Index, "Allergan Aesthetics CoolSculpting (Legacy/Gen 1-2) — pricing, FDA status and cost to own", aestheticindex.co (accessed November 23, 2026).

Get the full State of Aesthetic Devices 2026 report

A catalog of US-marketed aesthetic and wellness devices — preview it free.

Get the report

Explore this model’s specs and owner reviews. For new-equipment inquiries, browse current models.

Browse current models

Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.