Skip to content

Head to head

CO2RE vs AcuPulse (2026)

Compare purchase costs, running costs and the evidence behind each device.

Read the comparison overview
Purchase cost
No new-price range is on file for either CO2RE or AcuPulse. Request current quotes to compare purchase costs.
Practice fit
Both are listed under CO2 fractional/ablative. Check each model’s US regulatory status and labeled indications for your intended use.

CO2 Fractional/Ablative

View full device profile →

CO2 Fractional/Ablative

View full device profile →

Price comparison

New price range

Candela CO2RE
Not published
Lumenis AcuPulse
Not published

Used price reference

Candela CO2RE
$25k–$45kSource not documented
Lumenis AcuPulse
$25k–$50kSource not documented

Payback calculator

Candela CO2RE
View ROI calculator
Lumenis AcuPulse
View ROI calculator

Next step

Candela CO2RE
Lumenis AcuPulse

Supplies & running costs

Supplies & restrictions

Candela CO2RE

Supply pricing is not documented with a dated source yet. Request an itemized supply quote.

View running-cost details
Lumenis AcuPulse

None for standard aesthetic use (disposable tips exist for GYN applications). Budget eventual optics/arm service rather than per-case cost.

Source not documented

View running-cost details

FDA status & indications

FDA status & indication

Candela CO2RE
FDA record cited — see scopeK151655, K181523

Record scope: K181523 names the CO2RE Laser System and includes separate standard, fractional and surgical handpiece indications. K151655 is the earlier cited platform record. Included handpieces and applicable labeling determine scope; a platform clearance is not a statement that every accessory is supplied.

Read FDA indication wording
“The CO2RE is indicated for use in surgical applications requiring the ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: aesthetic surgery (dermatology and plastic surgery), podiatry, gynecology, neurosurgery, orthopedics (soft tissue), arthroscopy (knee). The CO2RE is indicated for dermatological procedures requiring ablation, coagulation and resurfacing of soft tissue, including skin. The Standard Handpiece of the CO2RE System is indicated for the following: Dermatology & Plastic Surgery The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of: x laser skin resurfacing x laser dermabrasion x laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) for the treatment of: x wrinkles, rhytids, and furrows (including fines lines and texture irregularities) Clinical literature demonstrates that skin resurfacing of wrinkles, rhytids, and furrows with CO2 laser increases the amount of sub-epidermal collagen.”
Lumenis AcuPulse
FDA record cited — see scopeK180597, K082809, K100415, K212703

Record scope: The October 19, 2021 record names the AcuPulse CO2 Laser System, delivery devices and accessories, and describes a modified AcuPulse family configuration. This summary highlights dermatologic uses; the full document lists additional surgical applications. Indication scope checked October 2, 2026; see the full labeling for the selected configuration.

Read FDA indication wording
“The Lumenis AcuPulse Family of CO2 Laser Systems, Delivery Devices and Accessories (AcuPulse, AcuPulse 40WG and AcuPulse DUO), is indicated for the vaporization, incision, excision, ablation or photocoagulation of soft tissue in the surgical specialties of: ENT, Gynecology, Laparoscopic Surgery including GYN Laparoscopy, Aesthetic Surgery, Dental and Oral Surgery, Neurosurgery, Orthopedics, General Surgery and Podiatry. The intended use of the Lumenis AcuPulse Family of CO2 Laser Systems, Delivery Devices and Accessories (AcuPulse, AcuPulse 40WG and AcuPulse DUO), is for the performance of specific surgical applications in the surgical specialties of ENT, Gynecology, Laparoscopic Surgery33 including GYN Laparoscopy, Aesthetic Surgery, Dental and Oral Surgery, Neurosurgery, Orthopedics, General Surgery and Podiatry as follows: Dermatology The Lumenis AcuPulse Family of CO2 Laser Systems, Delivery Devices and Accessories (AcuPulse, AcuPulse 40WG and AcuPulse DUO), is indicated for use in dermatology and plastic surgery for the following applications: • Ablation, vaporization, excision, incision and coagulation of soft tissue in the performance of: - Laser skin resurfacing - Laser dermabrasion - Laser burn debridement • Laser skin resurfacing (ablation and/or vaporization) for the treatment of: - Wrinkles, rhytids and furrows (including fine lines and texture irregularities). • Laser skin resurfacing (ablation, and/or vaporization) of soft tissue for the reduction, removal, and/or treatment of: - Keratosis, including actinic and seborrheic keratosis, seborrhoea vulgares, seborrheic wart and verruca seborrheica.”

Which chains run each

Chain adoption

Candela CO2RE
0 recorded pairings
Lumenis AcuPulse
0 recorded pairings

Chains using it

Candela CO2RE
—
Lumenis AcuPulse
—

Approved reviews

Candela CO2RE
0
Lumenis AcuPulse
0

Specs and platform

Manufacturer

Candela CO2RE
Candela
Lumenis AcuPulse
Lumenis

Built by (OEM)

Candela CO2RE
Syneron Medical Ltd.
Lumenis AcuPulse
Lumenis Be Ltd.

Category

Candela CO2RE
CO2 Fractional/Ablative
Lumenis AcuPulse
CO2 Fractional/Ablative

Technology

Candela CO2RE
Fractional CO2 10600nm dual-ring scanning (CO2 fractional)
Lumenis AcuPulse
CO2 10600nm fractional (SuperPulse) (CO2 fractional)

Launch year

Candela CO2RE
2011
Lumenis AcuPulse
2010

Status

Candela CO2RE
Current
Lumenis AcuPulse
Current

Manufacturing relationship evidence

Candela CO2RE
No separate manufacturing-relationship record linked.
Lumenis AcuPulse
No separate manufacturing-relationship record linked.

Current alternatives

Current catalog models in related categories. Confirm availability and configuration with the supplier.

Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.