Head to head
Hybrid vs UltraPulse Alpha (2026)
Compare purchase costs, running costs and the evidence behind each device.
Read the comparison overview
- Purchase cost
- No new-price range is on file for either Hybrid or UltraPulse Alpha. Request current quotes to compare purchase costs.
- Practice fit
- Both are listed under CO2 fractional/ablative. Check each model’s US regulatory status and labeled indications for your intended use.
CO2 Fractional/Ablative
View full device profile →CO2 Fractional/Ablative
View full device profile →Price comparison
New price range
- Alma Hybrid
- Not published
- Lumenis UltraPulse Alpha
- Not published
Used price reference
- Alma Hybrid
- $70k–$100kSource not documented
- Lumenis UltraPulse Alpha
- $70k–$110kSource not documented
Payback calculator
- Alma Hybrid
- View ROI calculator
- Lumenis UltraPulse Alpha
- View ROI calculator
Next step
Supplies & running costs
Supplies & restrictions
- Alma Hybrid
Supply pricing is not documented with a dated source yet. Request an itemized supply quote.
View running-cost details- Lumenis UltraPulse Alpha
Supply pricing is not documented with a dated source yet. Request an itemized supply quote.
View running-cost details
FDA status & indications
FDA status & indication
- Alma Hybrid
Record scope: 510(k): K203441 and K251230. Checked 4 Sep 2026.
Read FDA indication wording
“The Alma Hybrid Laser System, Delivery Devices, Applicators and Accessories are intended for use in surgical applications requiring the ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: aesthetic surgery (dermatology and plastic surgery). HyLight-CO2: The Alma Hybrid CO2 non-fractional applicator, with wavelength of 10600 nm is cleared for use for the particular indications as follows: Dermatology & Plastic Surgery — The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of: • laser skin resurfacing • laser derm-abrasion • laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) of soft tissue for the reduction, removal, and/or treatment of: warts, acne scars, nevi epidermal, syringoma. Vaporization/coagulation of warts. Pixel: The Alma Hybrid Pixel CO2 fractional applicator, with wavelength of 10600 nm is indicated for: The ablation, vaporization, and coagulation of soft tissue in dermatology and plastic surgery in the performance of skin resurfacing. ProScan: The Alma Hybrid ProScan CO2 fractional applicator, with wavelength of 10600 nm is indicated for: • Laser skin resurfacing (ablation and/or vaporization) of soft tissue. The Alma Hybrid ProScan 1570nm fractional applicator, with wavelength of 1570 nm, is indicated for: • Use in dermatological procedures requiring fractional skin resurfacing and coagulation of soft tissue. The Alma Hybrid ProScan CO2 & 1570nm fractional applicator, with wavelengths of 10600 nm & 1570nm is indicated for laser skin resurfacing (ablation and/or vaporization) of soft tissue.”
- Lumenis UltraPulse Alpha
- FDA ClearedK233301
Read FDA indication wording
“The Modified ULTRApulse Alpha CO2 Laser System, Delivery Devices and Accessories (members of the UltraPulse CO2 Laser Systems Family) is indicated for use in surgical or aesthetic applications requiring: ablation, vaporization, excision, incision, or coagulation of soft tissue in medical specialties including: dermatology and plastic surgery (aesthetic), podiatry, gynecology, general and thoracic surgery, dental and oral surgery and genitourinary surgery as follows: Dermatology & Plastic Surgery — The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of: • Laser skin resurfacing • Laser derm-abrasion • Laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) for treatment of: • Wrinkles, rhytids, and furrows (including fine lines and texture irregularities). Laser skin resurfacing (ablation and/or vaporization) of soft tissue for the reduction, removal, and/or treatment of: • Keratoses, including actinic and seborrheic keratosis, seborrhoecae vulgares, seborrheic wart and verruca seborrheica • Vermillionectomy of the lip • Cutaneous horns • Solar/actinic elastosis • Cheilitis, including actinic cheilitis • Lentigines, including lentigo maligna or Hutchinson's malignant freckle • Uneven pigmentation/dyschromia • Acne scars • Surgical scars • Keloids including acne keloidalis nuchae • Hemangiomas (including Buccal, port wine and pyogenic granulomas/granuloma pyogenicum/granuloma telangiectaticum) • Tattoos • Telangiectasia • Removal of small skin tumors, including periungual (Koenen) and subungual fibromas • Superficial pigmented lesions • Adenosebaceous hypertrophy or sebaceous hyperplasia • Rhinophyma reduction • Cutaneous papilloma (skin tags) • Milia • Debridement of eczematous or infected skin • Basal and squamous cell carcinoma, including keratoacanthomas, Bowen's disease (Erythroplasia of Queyrat), and Bowenoid Papulosis (BP) lesions • Nevi, including spider, epidermal and protruding • Neurofibromas • Laser de-epithelialization • Tricoepitheliomas • Xanthelasma palpebrarum […]”
Which chains run each
Chain adoption
- Alma Hybrid
- 0 recorded pairings
- Lumenis UltraPulse Alpha
- 0 recorded pairings
Chains using it
- Alma Hybrid
- —
- Lumenis UltraPulse Alpha
- —
Approved reviews
- Alma Hybrid
- 0
- Lumenis UltraPulse Alpha
- 0
Specs and platform
Manufacturer
- Alma Hybrid
- Alma
- Lumenis UltraPulse Alpha
- Lumenis
Built by (OEM)
- Alma Hybrid
- Alma Lasers Ltd.
- Lumenis UltraPulse Alpha
- Lumenis Be Ltd.
Category
- Alma Hybrid
- CO2 Fractional/Ablative
- Lumenis UltraPulse Alpha
- CO2 Fractional/Ablative
Technology
- Alma Hybrid
- CO2 10600nm + 1570nm fiber hybrid (CO2 fractional)
- Lumenis UltraPulse Alpha
- CO2 10600nm high-energy fractional (CO2 fractional)
Launch year
- Alma Hybrid
- 2021
- Lumenis UltraPulse Alpha
- 2019
Status
- Alma Hybrid
- Current
- Lumenis UltraPulse Alpha
- Current
Manufacturing relationship evidence
- Alma Hybrid
- No separate manufacturing-relationship record linked.
- Lumenis UltraPulse Alpha
- No separate manufacturing-relationship record linked.
Current alternatives
Current catalog models in related categories. Confirm availability and configuration with the supplier.
Candela CO2RE
CO2 Fractional/Ablative
New-equipment price not yet documented.
Cynosure Lutronic eCO2 3D
CO2 Fractional/Ablative
New-equipment price not yet documented.
DEKA HELIX
CO2 Fractional/Ablative
New-equipment price not yet documented.
DEKA SmartXide Punto
CO2 Fractional/Ablative
New-equipment price reference
$60k–$90k
Source not documentedCheck the profile for configuration and price details.
Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.