Viora V30 / V-FORM
RF body contouring · Modular RF, IPL and Nd:YAG platform; V-Form combines RF with massage.
At a glance
- New price
- $40k–$70kSource not documented
- FDA status
Record scope: K162363 explicitly names V30 and the V-Form BC Medium applicator; its enclosure specifies V-Form Small, Medium and Large applicators. K133837 is the earlier V-Total predicate. Scope depends on the installed handpiece; RF/massage labeling is not blanket clearance for fat reduction or all platform functions.
- Supplies & recurring costs
- See supply and replacement costs below.
Sources and data on file
Data on file
- Recurring consumables
- Not verified
- Used asking prices
- Not verified
- This panel shows a per-treatment supply cost only when a recorded figure has a dated source.
- Bottle prices and estimates may still appear under Treatment & running costs.
- The calculator may include a labeled planning estimate. Review it or enter your own allowance; missing data never means $0.
Figures are reference points, not current offers.
Read FDA-cleared indicationsExact wording from 1 FDA record
K133837 (Viora, Ltd., 2014)
The Viora V-total 7"' isintended for dermatological procedures. The ST handpiece is indicated for the treatment of relief of minor muscle aches and pain, relief of muscle spasm and temporary improvement of local blood circulation. The IPL handpiece with wavelengths 415-l200nm (with 5 different filters) is indicated for the treatment of:. * Moderate inflammatory acne vulgaris. * Benign pigmented epidermal lesions including dyschromia, hyperpigmentation, melasrna, and ephelides (freckles). * Cutaneous lesions including warts, scars and striae. "Benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacca, erythema of rosacca, angiomnas and spider angiomnas, poikiloderma of Civatte and venous malformations. * Removal unwanted hair. It is also intended for permanent reduction in unwanted hair. Permanent hair reduction is defined as the long-term stable reduction inthe number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regimen. The Nd:YAG Laser handpiece with wavelength 1064 nm comes with 4 different applicator spot diameters: 2x4, 3.5, 5.5 and 9.5 mm. The three smaller spot sizes (2x4, 3.5, 5.5 mm) are intended for: - Benign vascular lesions such as, but not limited to treatment of: port wine stains, hemangiomas, Warts, superficial and deep telangiectasias (venulectasias). reticular veins (0. 1-4.0mmn dia.) of the leg, rosace, venus lake, leg veins, spider veins, poikiloderma of civatte and angiomas. * Benign cutaneous lesions, such as, but not limited to: warts, scars, striae and psoriasis. * Benign pigmented lesions such as, but not limited to: lentigos (age spots), solar lentigos (sun spots), cafe-aulait macules, seborrheic keratosis, nevi and nevus of One, chloasma, verrucae, skin tags and keratosis. - Pigmented lesions to reduce lesion size, for patients with lesions that would potentially benefit from aggressive treatment, and for patients with lesions that have not responded to other laser treatments. ' The non-ablative treatment of facial wrinkles, such as, but not limited to: periocular wrinkles and perioral wrinkles. "The handpiece with a spot size of 9.5 mm is also intended for treatment of: Laser skin resurfacing procedures for the treatment of: acne scars and wrinkles. Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral pant of the scar.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
Page updated: October 7, 2026 · How we verify
Axis runs $0–$70k. Reference figures, not current offers.
Not verified
We hold no per-treatment consumable price for this device from a dated source. Ask the seller for a written per-treatment cost.
Price sourcesSources, dates and configurations
Key factsCompany, specifications and verification dates
| Manufacturer | Viora |
|---|---|
| Company | Owner: Sinclair Pharma, a wholly owned subsidiary of Huadong Medicine Co., Ltd. (subsidiary, since 2022) |
| Parent company | Sinclair Pharma (Huadong Medicine) |
| Brand owner | Viora |
| Built by (OEM) | Viora Ltd. |
| Category | Body Contouring |
| Technology | Modular RF, IPL and Nd:YAG platform; V-Form combines RF with massage. |
| FDA status | FDA record cited — see scope |
| 510(k) citation | K133837, K162363 |
| New price range | $40k–$70k |
| Used price reference | Not published |
| Consumables | Not published |
| Launch year | 2018 |
| Pricing | Not published |
| Manufacturer-source documents checked | Not published |
Company source
·Trade press · Updated Jun 1, 2023Sinclair's June 1, 2023 company-issued press release reports its acquisition of Viora and includes V-Series, Reaction and Pristine in its energy-device portfolio. This supports historical company attribution, not current sales or service availability or individual-device regulatory scope. The earlier acquisition-announcement link was unavailable when checked October 7, 2026.Overview
V30 is a modular platform with V-ST, V-IPL, V-Nd:YAG and V-Form handpieces described in K162363. Confirm which handpieces and applicators are included; the corresponding indications and maintenance requirements differ.
How it worksTechnology and manufacturing
How the technology works
CORE (Channeling Optimized RF Energy) switches between three RF frequencies — 0.8, 1.7, and 2.45MHz — plus a multi-channel mode: lower frequencies penetrate deeper, higher frequencies concentrate superficially, so one handpiece targets subcutaneous fat, deep dermis, or superficial dermis by dialing frequency.
V-FORM pairs CORE RF with vacuum that lifts tissue into the head, improving coupling and lymphatic drainage for cellulite and circumference work. Cumulative results over 4-8 weekly sessions with maintenance — a series-sale device.
Patented technology
Patented CORE multi-frequency RF architecture — most competitors run a single fixed frequency; the modular V-Series console design is the business-model differentiator.
Origin
Israel (Viora, now part of Sinclair); US HQ historically New Jersey.
FDA & regulatory detailClearance timeline, authorization route and citation notes
Source and verification notes
·FDA database · Updated Oct 6, 2026K162363 pages 3–9 directly names V30/V-Form and identifies V-Total K133837 as its predicate. Supersedes the earlier unresolved V30 mapping. The two existing catalog entries are retained; their prices and identities are unchanged. Selected fields only; this is not whole-profile verification.K162363 explicitly names V30 and the V-Form BC Medium applicator; its enclosure specifies V-Form Small, Medium and Large applicators. K133837 is the earlier V-Total predicate. Scope depends on the installed handpiece; RF/massage labeling is not blanket clearance for fat reduction or all platform functions.
FDA-cleared indications (verbatim)
K133837 (Viora, Ltd., 2014)
The Viora V-total 7"' isintended for dermatological procedures. The ST handpiece is indicated for the treatment of relief of minor muscle aches and pain, relief of muscle spasm and temporary improvement of local blood circulation. The IPL handpiece with wavelengths 415-l200nm (with 5 different filters) is indicated for the treatment of:. * Moderate inflammatory acne vulgaris. * Benign pigmented epidermal lesions including dyschromia, hyperpigmentation, melasrna, and ephelides (freckles). * Cutaneous lesions including warts, scars and striae. "Benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacca, erythema of rosacca, angiomnas and spider angiomnas, poikiloderma of Civatte and venous malformations. * Removal unwanted hair. It is also intended for permanent reduction in unwanted hair. Permanent hair reduction is defined as the long-term stable reduction inthe number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regimen. The Nd:YAG Laser handpiece with wavelength 1064 nm comes with 4 different applicator spot diameters: 2x4, 3.5, 5.5 and 9.5 mm. The three smaller spot sizes (2x4, 3.5, 5.5 mm) are intended for: - Benign vascular lesions such as, but not limited to treatment of: port wine stains, hemangiomas, Warts, superficial and deep telangiectasias (venulectasias). reticular veins (0. 1-4.0mmn dia.) of the leg, rosace, venus lake, leg veins, spider veins, poikiloderma of civatte and angiomas. * Benign cutaneous lesions, such as, but not limited to: warts, scars, striae and psoriasis. * Benign pigmented lesions such as, but not limited to: lentigos (age spots), solar lentigos (sun spots), cafe-aulait macules, seborrheic keratosis, nevi and nevus of One, chloasma, verrucae, skin tags and keratosis. - Pigmented lesions to reduce lesion size, for patients with lesions that would potentially benefit from aggressive treatment, and for patients with lesions that have not responded to other laser treatments. ' The non-ablative treatment of facial wrinkles, such as, but not limited to: periocular wrinkles and perioral wrinkles. "The handpiece with a spot size of 9.5 mm is also intended for treatment of: Laser skin resurfacing procedures for the treatment of: acne scars and wrinkles. Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral pant of the scar.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
Marketed for
RF body contouring — Multi-CORE RF + vacuum
Marketing claims are the manufacturer's own and are not the same as a cleared indication.
Parent company: Sinclair Pharma (Huadong Medicine)
Legal manufacturer: Viora Ltd. (Israel)
Applicant on the FDA record
Viora Ltd.The applicant named on the FDA record can differ from the brand shown on the device.
Regulatory data comes from public FDA records and may lag recent updates. Confirm the applicable status and documentation before purchase.
Treatment & running costs
Supplies & recurring costs
Viora’s V-FORM brochure describes interchangeable small, medium and large applicators. Confirm approved treatment supplies and maintenance for each handpiece included with the V30 console.
The brochure does not provide a consumables or replacement-price schedule; V-FORM costs should not be generalized to every V30 attachment.
Source notes
Historical manufacturer-authored brochure MK-236 CE D identifies interchangeable V-FORM applicators but contains no consumables price schedule. It does not establish costs for all V30 modules.
Not yet documented: session schedule, treatment pricing, annual service costs.
Payback calculatorEnter your quote, volume and running costs
Estimate your payback
Enter your quote and treatment costs for Viora V30 / V-FORM. Published figures appear where available; review them before using the estimate.
Start from
No verified per-treatment supply cost is on file. Enter your own allowance. Use $0 only if you have confirmed that it applies to your practice.
Pre-filled from the midpoint of the published new-price range
20 is an illustrative default — change it to your volume.
No sourced per-session price on file — enter what you charge.
Required — enter your cost; missing data does not mean $0.
Required — include staff time and your own time. Enter 0 only to explicitly exclude labor from this estimate.
Annual service contract ÷ 12, if you carry one.
Your estimate
Enter price you charge per treatment, consumable cost per treatment, labor cost per treatment to see contribution and a payback range.
This model ignores financing — if you lease or borrow, add your monthly payment. Estimates from your inputs and our published ranges — not a projection, guarantee or financial advice. How we calculate this.
Screening considerationsCatalog notes to check against the current instructions for use
Catalog screening notes
Pregnancy, pacemakers and implanted metal in the field, active malignancy, acute skin conditions in the area; vacuum applicators need caution with fragile capillaries and anticoagulated patients.
These notes are not a complete or verified manufacturer contraindication list. Use the current instructions for the exact device and applicator to determine contraindications, warnings and patient eligibility.
Warranty & serviceWhat to confirm in writing before you buy
Before buying new or used, confirm in writing:
- Current warranty coverage
- Included training
- Service terms
Chains using this device
A chain listing does not establish availability at every location.
No confirmed chain deployments recorded yet.
Owner & operator reviews
Write a reviewNo owner or operator reviews yet. Be the first →
Current alternatives
Current catalog models to research. Confirm availability and configuration with the supplier.
History13 tracked changes
Every tracked change to pricing, lifecycle status, FDA data and warranty terms — newest first.
October 7, 2026
Source recovery and scope reconciliation 2026-10-07
Recovered source and reconciled citation scope after direct source inspection. Device fields and equipment prices are unchanged.
Source: https://www.prweb.com/releases/global-medical-aesthetic-company-sinclair-launches-in-canada-812213765.html
October 7, 2026
Ownership cost clarity 2026-10-07
Manufacturer-authored V-FORM brochure MK-236 CE D, hosted by Medilase, reviewed October 7, 2026. Removed unsupported near-zero consumables and several-thousand-dollar handpiece cost. No current price or US package is inferred from the historical brochure.
Source: https://medilase.co.za/wp-content/uploads/2021/07/V-FORM-Brochure-MK-236-CE-D-Low.pdf
October 6, 2026
FDA K-numbers
K133837 → K133837; K162363
Source: Catalog update
October 6, 2026
FDA indication
Source: Catalog update
October 6, 2026
FDA source URL
https://www.accessdata.fda.gov/cdrh_docs/pdf13/K133837.pdf → https://www.accessdata.fda.gov/cdrh_docs/pdf16/K162363.pdf
Source: Catalog update
October 6, 2026
Council Batch 02 evidence corrections
Reviewed changed fields only on October 6, 2026. Unchanged equipment prices and other fields are not reverified. Scope, generation, region and offer terms remain specific to each source. Additional sources: https://www.accessdata.fda.gov/cdrh_docs/pdf13/K133837.pdf
Source: https://www.accessdata.fda.gov/cdrh_docs/pdf16/K162363.pdf
October 6, 2026
fda status council batch 02 evidence
Claim-specific evidence; not a whole-profile verification.
Source: https://www.accessdata.fda.gov/cdrh_docs/pdf16/K162363.pdf
October 6, 2026
FDA indication
Source: Catalog update
October 6, 2026
FDA source URL
https://www.accessdata.fda.gov/cdrh_docs/pdf13/K133837.pdf
Source: Catalog update
October 6, 2026
fda status batch 02 platform indications evidence
Claim-specific evidence; not a whole-profile verification.
Source: https://www.accessdata.fda.gov/cdrh_docs/pdf13/K133837.pdf
September 7, 2026
parent company
Viora → Sinclair Pharma (Huadong Medicine)
Ultimate owner updated against a dated primary source (8 Sep 2026).
Source: https://sinclair.com/news/sinclair-announces-acquisition-of-viora/
August 5, 2026
Warranty & service
Source: Catalog update
August 1, 2026
Record created
Added to The Aesthetic Index — August 2026
Source: The Aesthetic Index editorial
Cite this data: The Aesthetic Index, "Viora V30 / V-FORM — pricing, FDA status and cost to own", aestheticindex.co (accessed November 23, 2026).
Get the full State of Aesthetic Devices 2026 report
A catalog of US-marketed aesthetic and wellness devices — preview it free.
Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.