Viora Reaction
RF body contouring · Bipolar RF (CORE) + vacuum
At a glance
- New-unit reference · older model
- Not published
- Used asking price
- $5k–$15kSource not documented
- FDA status
Record scope: K090221 separates Reaction applicators. B-contour/F-contour include temporary cellulite-appearance reduction plus pain/spasm/circulation uses; the ST applicator has the latter uses. This record does not establish circumference reduction or a cosmetic-tightening indication.
- Supplies & recurring costs
- Supply details not yet documented.
Sources and data on file
Data on file
- Recurring consumables
- Not verified
- FDA
- FDA record cited — see scopeK090221
- Used asking prices
- Not verified
- This panel shows a per-treatment supply cost only when a recorded figure has a dated source.
- Bottle prices and estimates may still appear under Treatment & running costs.
- The calculator may include a labeled planning estimate. Review it or enter your own allowance; missing data never means $0.
Figures are reference points, not current offers. Used asking prices are not completed-sale values.
Read FDA-cleared indicationsExact wording from 1 FDA record
K090221 (Viora, Ltd., 2009)
The :Reaction TM system is intended for the treatment ol'the iollowintg medicd conditionsS, usi1g the B-contour and F-contour applicators for deiivering non thermal RF combined with massage: - relief of minor muscle aches and pain, relief of muscie spasm, temporary improvement. o'local blood cii'iulation, and - te.mporary reduction in the appearance of cellutite. ising- the SI ' applicator :or delivering RF, the Reaction T M system is intended for the treatment of relief of minor muscle aches and pain.. relief of.muscle spasm,.temporary improvement of local blood circulation. ]l:iesci'iption.Uise.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
Page updated: October 7, 2026 · How we verify
Older-model price not documented
Use the ownership information below and compare current models.
Axis runs $0–$15k. Reference figures, not current offers. Used asking prices are not completed-sale values.
Not verified
We hold no per-treatment consumable price for this device from a dated source. Ask the seller for a written per-treatment cost.
Price sourcesSources, dates and configurations
Key factsCompany, specifications and verification dates
| Manufacturer | Viora |
|---|---|
| Company | Owner: Sinclair Pharma, a wholly owned subsidiary of Huadong Medicine Co., Ltd. (subsidiary, since 2022) |
| Parent company | Sinclair Pharma (Huadong Medicine) |
| Brand owner | Viora |
| Built by (OEM) | Viora Ltd. |
| Category | Body Contouring |
| Technology | Bipolar RF (CORE) + vacuum |
| FDA status | FDA record cited — see scope |
| 510(k) citation | K090221 |
| New-unit reference (older model) | Not published |
| Used price reference | $5k–$15k |
| Consumables | Not published |
| Launch year | 2010 |
| Pricing | Not published |
| Manufacturer-source documents checked | Not published |
Company source
·Trade press · Updated Jun 1, 2023Sinclair's June 1, 2023 company-issued press release reports its acquisition of Viora and includes V-Series, Reaction and Pristine in its energy-device portfolio. This supports historical company attribution, not current sales or service availability or individual-device regulatory scope. The earlier acquisition-announcement link was unavailable when checked October 7, 2026.Overview
Reaction uses RF treatment applicators, including configurations combined with massage. Its B-contour, F-contour and ST applicators have different cleared uses; identify which are included and supported.
FDA & regulatory detailClearance timeline, authorization route and citation notes
Source and verification notes
·FDA database · Updated Oct 7, 2026K090221 separates Reaction applicators. B-contour/F-contour include temporary cellulite-appearance reduction plus pain/spasm/circulation uses; the ST applicator has the latter uses. This record does not establish circumference reduction or a cosmetic-tightening indication. Additional sources: . Only the stated fields were reviewed; not whole-profile verification.K090221 separates Reaction applicators. B-contour/F-contour include temporary cellulite-appearance reduction plus pain/spasm/circulation uses; the ST applicator has the latter uses. This record does not establish circumference reduction or a cosmetic-tightening indication.
FDA-cleared indications (verbatim)
K090221 (Viora, Ltd., 2009)
The :Reaction TM system is intended for the treatment ol'the iollowintg medicd conditionsS, usi1g the B-contour and F-contour applicators for deiivering non thermal RF combined with massage: - relief of minor muscle aches and pain, relief of muscie spasm, temporary improvement. o'local blood cii'iulation, and - te.mporary reduction in the appearance of cellutite. ising- the SI ' applicator :or delivering RF, the Reaction T M system is intended for the treatment of relief of minor muscle aches and pain.. relief of.muscle spasm,.temporary improvement of local blood circulation. ]l:iesci'iption.Uise.
Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.
Marketed for
RF body contouring — Bipolar RF (CORE) + vacuum
Marketing claims are the manufacturer's own and are not the same as a cleared indication.
Parent company: Sinclair Pharma (Huadong Medicine)
Legal manufacturer: Viora Ltd. (Israel)
Applicant on the FDA record
Viora, Ltd.The applicant named on the FDA record can differ from the brand shown on the device.
Regulatory data comes from public FDA records and may lag recent updates. Confirm the applicable status and documentation before purchase.
Treatment & running costs
Treatment and running-cost details aren’t documented yet.
Ask the supplier for the session schedule, supplies per treatment and annual service costs.
Use your own figures in the calculatorPayback calculatorEnter your quote, volume and running costs
Estimate your payback
Enter your quote and treatment costs for Viora Reaction. Published figures appear where available; review them before using the estimate.
Start from
No verified per-treatment supply cost is on file. Enter your own allowance. Use $0 only if you have confirmed that it applies to your practice.
Pre-filled from the midpoint of the published used asking range
20 is an illustrative default — change it to your volume.
No sourced per-session price on file — enter what you charge.
Required — enter your cost; missing data does not mean $0.
Required — include staff time and your own time. Enter 0 only to explicitly exclude labor from this estimate.
Annual service contract ÷ 12, if you carry one.
Your estimate
Enter price you charge per treatment, consumable cost per treatment, labor cost per treatment to see contribution and a payback range.
This model ignores financing — if you lease or borrow, add your monthly payment. Estimates from your inputs and our published ranges — not a projection, guarantee or financial advice. How we calculate this.
Warranty & serviceWhat to confirm in writing before you buy
Before buying new or used, confirm in writing:
- Current warranty coverage
- Included training
- Service terms
Chains using this device
A chain listing does not establish availability at every location.
No confirmed chain deployments recorded yet.
Owner & operator reviews
Write a reviewNo owner or operator reviews yet. Be the first →
Current alternatives
Current catalog models to research. Confirm availability and configuration with the supplier.
History11 tracked changes
Every tracked change to pricing, lifecycle status, FDA data and warranty terms — newest first.
October 7, 2026
Source recovery and scope reconciliation 2026-10-07
Recovered source and reconciled citation scope after direct source inspection. Device fields and equipment prices are unchanged.
Source: https://www.prweb.com/releases/global-medical-aesthetic-company-sinclair-launches-in-canada-812213765.html
October 7, 2026
Batch 04 primary-source corrections
Reviewed changed fields only on October 7, 2026. Unchanged equipment prices and other fields are not reverified. Scope, generation, region and offer terms remain specific to each source.
Source: https://www.accessdata.fda.gov/cdrh_docs/pdf9/K090221.pdf
October 7, 2026
FDA indication
Source: Catalog update
October 7, 2026
FDA source URL
https://www.accessdata.fda.gov/cdrh_docs/pdf9/K090221.pdf
Source: Catalog update
October 7, 2026
fda status batch 04 primary-source evidence
Claim-specific evidence; not a whole-profile verification.
Source: https://www.accessdata.fda.gov/cdrh_docs/pdf9/K090221.pdf
September 7, 2026
parent company
Viora → Sinclair Pharma (Huadong Medicine)
Ultimate owner updated against a dated primary source (8 Sep 2026).
Source: https://sinclair.com/news/sinclair-announces-acquisition-of-viora/
August 30, 2026
FDA K-numbers
Source: Catalog update
August 5, 2026
FDA status
Unknown → Cleared
Source: Catalog update
August 5, 2026
FDA indication
Bipolar RF + vacuum: cellulite appearance, circumference reduction, tightening
Source: Catalog update
August 5, 2026
FDA K-numbers
Source: Catalog update
August 1, 2026
Record created
Added to The Aesthetic Index — August 2026
Source: The Aesthetic Index editorial
Cite this data: The Aesthetic Index, "Viora Reaction — pricing, FDA status and cost to own", aestheticindex.co (accessed November 23, 2026).
Get the full State of Aesthetic Devices 2026 report
A catalog of US-marketed aesthetic and wellness devices — preview it free.
Explore this model’s specs and owner reviews. For new-equipment inquiries, browse current models.
Browse current modelsDevice and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.