Skip to content

Solta Fraxel re:store (SR1500)

Non-Ablative Fractional · 1550nm erbium-glass fractional

Technology: Erbium Laser

Classification & configurations

Category group: Resurfacing & pigment (ablative, fractional, picosecond, vascular)

Legacy model

At a glance

New-unit reference · older model
Not published
Used asking price
$10k–$22kSource not documented
FDA status

Record scope: Primary clearance: K091420 (FRAXEL RE:STORE LASER SYSTEM, MODEL SR1500, decision 14 Oct 2009). K062303 and K050841 are earlier family clearances. Checked 4 Sep 2026.

Supplies & recurring costs
See supply and replacement costs below.
View supply details
Sources and data on file

Data on file

Recurring consumables
Not verified
FDA
FDA record cited — see scopeK091420, K062303, K050841
Used asking prices
Not verified
  • This panel shows a per-treatment supply cost only when a recorded figure has a dated source.
  • Bottle prices and estimates may still appear under Treatment & running costs.
  • The calculator may include a labeled planning estimate. Review it or enter your own allowance; missing data never means $0.

Figures are reference points, not current offers. Used asking prices are not completed-sale values.

Read FDA-cleared indicationsExact wording from 3 FDA records

K091420 (Solta Medical, Inc., 2009)

Fraxel re:store (SR 1500) Laser System and Accessories 1550 nm: The Fraxel re:store 1550 nm laser is indicated for use in dermatological procedures requiring the coagulation of soft tissue, as well as for skin resurfacing procedures. It also indicated for treatment of dyschromia and cutaneous lesions, such as, but not limited to lentigos (age spots), solar lentigos (sun spots), actinic keratosis, and melasma, and for treatment of periorbital wrinkles, acne scars and surgical scars. 1925 nm: The Fraxel re:store 1925 nm laser is indicated for use in dermatological procedures requiring the coagulation of soft tissue.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K062303 (Reliant Technologies, Inc., 2007)

STATEMENT The Fraxel II SR Laser System is intended for use in: Dermatological procedures requiring the coagulation of soft tissue; Treatment of periorbital wrinkles; Treatment of acne scars and surgical scars; Photocoagulation of pigmented lesions, such as, but not limited to lentigos (age spots), solar lentigos (sun spots) and dyschromia; Skin resurfacing procedures.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K050841 (Reliant Technologies, Inc., 2005)

The Reliant Laser System II is intended for use in: Dermatological procedures requiring the coaguilation of soft tissue; Treatment of periorbital wrinkles; Photocoagulation of pigmented lesions, such as, but not limited to lentigos (age spots), solar lentigos (sun spots), melasma and dyschromia; Skin resurfacing procedures.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

Page updated: October 1, 2026 · How we verify

Older-model price not documented

Use the ownership information below and compare current models.

Used asking price reference
Used$10k–$22k
Source not documented

Axis runs $0–$22k. Reference figures, not current offers. Used asking prices are not completed-sale values.

Consumable cost per treatment

Not verified

We hold no per-treatment consumable price for this device from a dated source. Ask the seller for a written per-treatment cost.

Price sourcesSources, dates and configurations
Used price reference: $10k–$22k·Researched estimate — no dated source on file yet; not a quote.
Key factsCompany, specifications and verification dates
Key facts
ManufacturerSolta
CompanyOwner: Bausch Health Companies Inc. (NYSE/TSX: BHC) (subsidiary, since 2014) · Distribution: direct
Parent companySolta Medical (Bausch Health)
Brand ownerSolta
Built by (OEM)Solta Medical Inc.
CategoryNon-Ablative Fractional
Technology1550nm erbium-glass fractional
FDA statusFDA record cited — see scope
510(k) citationK091420, K062303, K050841
New-unit reference (older model)Not published
Used price reference$10k–$22k
ConsumablesNot published
Launch year2007
PricingNot published
Manufacturer-source documents checkedNot published

Overview

This is a legacy Fraxel resurfacing profile. The cited FDA records describe SR-family fiber-laser systems that deliver patterned thermal energy.

For a used SR1500, match the unit’s model label and instructions to its accessories and regulatory records.

How it worksTechnology and manufacturing

How the technology works

Non-ablative fractional photothermolysis: a 1550nm erbium-doped fiber laser drills thousands of microscopic coagulated columns into the dermis while sparing surrounding tissue, triggering collagen remodeling without an open wound. Downtime is redness, swelling, bronzed flaking for 3-7 days.

This is the platform much of the fractional literature was written on.

Patented technology

Built on the foundational Manstein/Anderson fractional-photothermolysis IP that named the entire category; Intelligent Optical Tracking meters microbeam delivery as the operator rolls the handpiece — and eliminated the messy OptiGuide Blue dye the original SR750 required.

Origin

Reliant Technologies, Mountain View/Hayward, California; later Solta Medical.

FDA & regulatory detailClearance timeline, authorization route and citation notes
Authorized via 510(k)

Primary clearance: K091420 (FRAXEL RE:STORE LASER SYSTEM, MODEL SR1500, decision 14 Oct 2009). K062303 and K050841 are earlier family clearances. Checked 4 Sep 2026.

FDA-cleared indications (verbatim)

K091420 (Solta Medical, Inc., 2009)

Fraxel re:store (SR 1500) Laser System and Accessories 1550 nm: The Fraxel re:store 1550 nm laser is indicated for use in dermatological procedures requiring the coagulation of soft tissue, as well as for skin resurfacing procedures. It also indicated for treatment of dyschromia and cutaneous lesions, such as, but not limited to lentigos (age spots), solar lentigos (sun spots), actinic keratosis, and melasma, and for treatment of periorbital wrinkles, acne scars and surgical scars. 1925 nm: The Fraxel re:store 1925 nm laser is indicated for use in dermatological procedures requiring the coagulation of soft tissue.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K062303 (Reliant Technologies, Inc., 2007)

STATEMENT The Fraxel II SR Laser System is intended for use in: Dermatological procedures requiring the coagulation of soft tissue; Treatment of periorbital wrinkles; Treatment of acne scars and surgical scars; Photocoagulation of pigmented lesions, such as, but not limited to lentigos (age spots), solar lentigos (sun spots) and dyschromia; Skin resurfacing procedures.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

K050841 (Reliant Technologies, Inc., 2005)

The Reliant Laser System II is intended for use in: Dermatological procedures requiring the coaguilation of soft tissue; Treatment of periorbital wrinkles; Photocoagulation of pigmented lesions, such as, but not limited to lentigos (age spots), solar lentigos (sun spots), melasma and dyschromia; Skin resurfacing procedures.

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

Marketed for

Erbium — 1550nm erbium-glass fractional

Marketing claims are the manufacturer's own and are not the same as a cleared indication.

510(k) applicant of record: Reliant Technologies, Inc. (became Solta Medical)

Parent company: Solta Medical (Bausch Health)

Legal manufacturer: Solta Medical Inc. (United States)

Applicant on the FDA record

Reliant Technologies / Solta MedicalThe applicant named on the FDA record can differ from the brand shown on the device.

Regulatory data comes from public FDA records and may lag recent updates. Confirm the applicable status and documentation before purchase.

Treatment & running costs

Supplies & recurring costs

Supply pricing is not documented with a dated source yet. Request an itemized supply quote.

Not yet documented: session schedule, treatment pricing, annual service costs.

Payback calculatorEnter your quote, volume and running costs

Estimate your payback

Enter your quote and treatment costs for Solta Fraxel re:store (SR1500). Published figures appear where available; review them before using the estimate.

Start from

No verified per-treatment supply cost is on file. Enter your own allowance. Use $0 only if you have confirmed that it applies to your practice.

Pre-filled from the midpoint of the published used asking range

20 is an illustrative default — change it to your volume.

No sourced per-session price on file — enter what you charge.

Required — enter your cost; missing data does not mean $0.

Required — include staff time and your own time. Enter 0 only to explicitly exclude labor from this estimate.

Annual service contract ÷ 12, if you carry one.

Your estimate

Enter price you charge per treatment, consumable cost per treatment, labor cost per treatment to see contribution and a payback range.

This model ignores financing — if you lease or borrow, add your monthly payment. Estimates from your inputs and our published ranges — not a projection, guarantee or financial advice. How we calculate this.

Screening considerationsCatalog notes to check against the current instructions for use

Catalog screening notes

Isotretinoin within 6-12 months, pregnancy, active infection (HSV prophylaxis perioral), keloid history; treat Fitzpatrick IV-VI conservatively on density and energy for PIH.

These notes are not a complete or verified manufacturer contraindication list. Use the current instructions for the exact device and applicator to determine contraindications, warnings and patient eligibility.

Warranty & serviceWhat to confirm in writing before you buy

Before buying new or used, confirm in writing:

  • Current warranty coverage
  • Included training
  • Service terms

Chains using this device

A chain listing does not establish availability at every location.

No confirmed chain deployments recorded yet.

Owner & operator reviews

Write a review

No owner or operator reviews yet. Be the first →

Current alternatives

Current catalog models to research. Confirm availability and configuration with the supplier.

Lumenis ResurFX (M22/Stellar module)

Non-Ablative Fractional

New-equipment price not yet documented.

Cynosure Lutronic Mosaic 3D

Non-Ablative Fractional

New-equipment price not yet documented.

History9 tracked changes

Every tracked change to pricing, lifecycle status, FDA data and warranty terms — newest first.

  1. October 1, 2026

    Profile overview and accuracy audit

    Added a neutral sourced overview. This is field-specific sourcing, not verification of every other profile field or an endorsement of health-outcome claims.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf6/K062303.pdf

  2. September 4, 2026

    consumables detail

    Manufacturer-conduct language removed or restated as a dated, sourced fact.

    Source: Editorial sweep 2026-09-04: manufacturer-conduct language neutralized

  3. September 4, 2026

    notes

    Second-gen workhorse Fraxel → removed

    Unsourced evaluative sentence removed under the opinion-layer gate.

    Source: Catalog update — Wave D opinion-layer gate, 2026-09-04

  4. September 4, 2026

    science

    Unsourced evaluative sentence removed under the opinion-layer gate.

    Source: Catalog update — Wave D opinion-layer gate, 2026-09-04

  5. September 4, 2026

    510(k) numbers

    K-number set re-verified against openFDA

    Source: Council round 2 audit, verified on openFDA 2026-09-04

  6. September 4, 2026

    FDA K-numbers

    Source: Catalog update

  7. September 4, 2026

    FDA source URL

    Source: Catalog update

  8. August 5, 2026

    Warranty & service

    Source: Catalog update

  9. August 1, 2026

    Record created

    Added to The Aesthetic Index — August 2026

    Source: The Aesthetic Index editorial

Cite this data: The Aesthetic Index, "Solta Fraxel re:store (SR1500) — pricing, FDA status and cost to own", aestheticindex.co (accessed November 23, 2026).

Get the full State of Aesthetic Devices 2026 report

A catalog of US-marketed aesthetic and wellness devices — preview it free.

Get the report

Explore this model’s specs and owner reviews. For new-equipment inquiries, browse current models.

Browse current models

Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.