Cocoon Medical Primelase Excellence/HR

Diode laser · Diode laser platform with applicator-dependent wavelengths. K201594 describes Primelase Excellence options at 755 nm, 810 nm, 1060 nm and 810–1060 nm; confirm the installed applicator and any HR-generation differences.

Technology: Diode Laser

Classification & configurations

Category group: Hair removal (diode, alexandrite, Nd:YAG, IPL)

Current

At a glance

New price
$60k–$95kSource not documented
FDA status

Record scope: K191321 and K201594 concern Primelase Excellence. K201594 adds applicator-specific indications; these must not be transferred to every wavelength or to an HR unit without matching its labeling.

Supplies & recurring costs
See supply and replacement costs below.
View supply details
Used-market price reference
Used asking price
$30k–$50kSource not documented

Used asking prices are research references, not completed-sale values or available inventory.

Sources and data on file

Data on file

Recurring consumables
Not verified
FDA
FDA record cited — see scopeK191321, K201594
Used asking prices
Not verified
  • This panel shows a per-treatment supply cost only when a recorded figure has a dated source.
  • Bottle prices and estimates may still appear under Treatment & running costs.
  • The calculator may include a labeled planning estimate. Review it or enter your own allowance; missing data never means $0.

Figures are reference points, not current offers.

·FDA database · Updated Oct 6, 2026
Read FDA-cleared indicationsExact wording from 1 FDA record

K191321 (High Technology Products S.L.U, 2019)

include: • Hair Removal with Static and Dynamic modes intended for permanent reduction in hair regrowth, defined as a long term, stable reduction in the number of hairs re-growing when measured at 6, 9, and 12 months after the completion of a treatment regime. • Treatment of Pseudofolliculitis barbae (PFB). • Use on all skin types (Fitzpatrick I-VI).

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

Page updated: October 6, 2026 · How we verify

Compare new and used price references
New and used price references
New$60k–$95k
Source not documented
Used$30k–$50k
Source not documented

Axis runs $0–$95k. Reference figures, not current offers. Used asking prices are not completed-sale values.

Consumable cost per treatment

Not verified

We hold no per-treatment consumable price for this device from a dated source. Ask the seller for a written per-treatment cost.

Price sourcesSources, dates and configurations
New: $60k–$95k·Researched estimate — no dated source on file yet; not a quote.
Used price reference: $30k–$50k·Researched estimate — no dated source on file yet; not a quote.
Key factsCompany, specifications and verification dates
Key facts
ManufacturerCocoon Medical
CompanyOwner: Huadong Medicine Co., Ltd. (SZ: 000963), via Huadong Medicine Aesthetics Investment HK Ltd (subsidiary, since 2018) · Distribution: hybrid (direct + distributor)
Parent companySinclair
Brand ownerCocoon Medical
Built by (OEM)Cocoon Medical S.L.
CategoryDiode laser
TechnologyDiode laser platform with applicator-dependent wavelengths. K201594 describes Primelase Excellence options at 755 nm, 810 nm, 1060 nm and 810–1060 nm; confirm the installed applicator and any HR-generation differences.
FDA statusFDA record cited — see scope
510(k) citationK191321, K201594
New price range$60k–$95k
Used price reference$30k–$50k
ConsumablesNot published
Launch year2016
PricingNot published
Manufacturer-source documents checkedNot published

Overview

Primelase Excellence is a diode laser system with removable applicators and contact cooling through a sapphire window. The FDA record describes static and dynamic delivery modes.

Confirm the wavelength/applicator configuration, cooling requirements and service arrangements of the actual unit.

How it worksTechnology and manufacturing

How the technology works

High peak power is the core thesis: 4,800W through large apertures hits effective follicular fluences with very short pulse durations, better matching the thermal relaxation time of coarse hair while sparing the epidermis.

Patented technology

Cocoon's high-peak-power diode stack architecture and intensified contact-cooling tip design enabling the short-pulse/high-fluence protocols the brand is known for; the configurable multi-wavelength handpiece system is proprietary to the platform.

Origin

Barcelona, Spain (Cocoon Medical, now under the Sinclair umbrella).

FDA & regulatory detailClearance timeline, authorization route and citation notes

Source and verification notes

·FDA database · Updated Oct 6, 2026K201594 pages 6–7 adds applicator-specific indications to the earlier Excellence record K191321. HR configuration applicability remains subject to matching labeling. Selected fields only; this is not whole-profile verification.
Authorized via 510(k)

K191321 and K201594 concern Primelase Excellence. K201594 adds applicator-specific indications; these must not be transferred to every wavelength or to an HR unit without matching its labeling.

FDA-cleared indications (verbatim)

K191321 (High Technology Products S.L.U, 2019)

include: • Hair Removal with Static and Dynamic modes intended for permanent reduction in hair regrowth, defined as a long term, stable reduction in the number of hairs re-growing when measured at 6, 9, and 12 months after the completion of a treatment regime. • Treatment of Pseudofolliculitis barbae (PFB). • Use on all skin types (Fitzpatrick I-VI).

Verbatim from the FDA 510(k) summary, retrieved 8 Sep 2026.

Marketed for

Diode laser — 755/810/940/1060nm high-power diode

Marketing claims are the manufacturer's own and are not the same as a cleared indication.

510(k) holder of record

510(k) holder of record: High Technology Products S.L.U — Cocoon Medical markets, supports and warranties the device in the US.

Parent company: Sinclair

Legal manufacturer: Cocoon Medical S.L. (Spain)

Applicant on the FDA record

High Technology Products S.L.UThe applicant named on the FDA record can differ from the brand shown on the device.

Regulatory data comes from public FDA records and may lag recent updates. Confirm the applicable status and documentation before purchase.

Treatment & running costs

Supplies & recurring costs

No per-shot consumables; ongoing costs limited to gel and eventual handpiece/diode service — near-zero marginal treatment cost, the whole point of high-power diode ownership.

Not yet documented: session schedule, treatment pricing, annual service costs.

Payback calculatorEnter your quote, volume and running costs

Estimate your payback

Enter your quote and treatment costs for Cocoon Medical Primelase Excellence/HR. Published figures appear where available; review them before using the estimate.

Start from

No verified per-treatment supply cost is on file. Enter your own allowance. Use $0 only if you have confirmed that it applies to your practice.

Pre-filled from the midpoint of the published new-price range

20 is an illustrative default — change it to your volume.

No sourced per-session price on file — enter what you charge.

Required — enter your cost; missing data does not mean $0.

Required — include staff time and your own time. Enter 0 only to explicitly exclude labor from this estimate.

Annual service contract ÷ 12, if you carry one.

Your estimate

Enter price you charge per treatment, consumable cost per treatment, labor cost per treatment to see contribution and a payback range.

This model ignores financing — if you lease or borrow, add your monthly payment. Estimates from your inputs and our published ranges — not a projection, guarantee or financial advice. How we calculate this.

Screening considerationsCatalog notes to check against the current instructions for use

Catalog screening notes

Pregnancy, active or recent tan, photosensitizing medications, active cutaneous infection, tattoos in the field, non-pigmented hair; the 1060nm option de-risks darker types, but conservative test spots on Fitzpatrick VI remain best practice at this power class.

These notes are not a complete or verified manufacturer contraindication list. Use the current instructions for the exact device and applicator to determine contraindications, warnings and patient eligibility.

Warranty & serviceWhat to confirm in writing before you buy

Published warranty details

A Cocoon Medical brochure, revision 20190125, lists a one-year warranty. This historical brochure does not establish current US coverage or annual service pricing; obtain the applicable terms, exclusions and service quote for the specific unit.

·Manufacturer-provided · Updated Oct 6, 2026
Source notes

Manufacturer brochure hosted by Medical Vision, page 11, lists one year; page 12 revision is 20190125. Historical, not current US contractual terms.

Removes unsupported current service estimates. Selected fields only; this is not whole-profile verification.

Before buying new or used, confirm in writing:

  • Current warranty coverage
  • Included training
  • Service terms

Chains using this device

A chain listing does not establish availability at every location.

No confirmed chain deployments recorded yet.

Owner & operator reviews

Write a review

No owner or operator reviews yet. Be the first →

Current alternatives

Current catalog models to research. Confirm availability and configuration with the supplier.

Asclepion MeDioStar (monolith)

Diode laser

New-equipment price reference

$80k–$110k

Source not documented

Check the profile for configuration and price details.

Cynosure Vectus

Diode laser

New-equipment price not yet documented.

Research comparisons

Includes current and older models.

History15 tracked changes

Every tracked change to pricing, lifecycle status, FDA data and warranty terms — newest first.

  1. October 6, 2026

    Council Batch 02 specifications

    Reviewed changed fields only on October 6, 2026. Unchanged equipment prices and other fields are not reverified. Scope, generation, region and offer terms remain specific to each source.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf20/K201594.pdf

  2. October 6, 2026

    FDA source URL

    https://www.accessdata.fda.gov/cdrh_docs/pdf19/K191321.pdf → https://www.accessdata.fda.gov/cdrh_docs/pdf20/K201594.pdf

    Source: Catalog update

  3. October 6, 2026

    FDA K-numbers

    K191321 → K191321; K201594

    Source: Catalog update

  4. October 6, 2026

    fda status council batch 02 evidence

    Claim-specific evidence; not a whole-profile verification.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf20/K201594.pdf

  5. October 6, 2026

    warranty service council batch 02 evidence

    Claim-specific evidence; not a whole-profile verification.

    Source: https://medicalvisiononline.com/wp-content/uploads/2022/08/Brochure-Primelase.pdf

  6. October 6, 2026

    FDA indication

    Source: Catalog update

  7. October 6, 2026

    Warranty & service

    Source: Catalog update

  8. October 6, 2026

    Council Batch 02 evidence corrections

    Reviewed changed fields only on October 6, 2026. Unchanged equipment prices and other fields are not reverified. Scope, generation, region and offer terms remain specific to each source. Additional sources: https://www.accessdata.fda.gov/cdrh_docs/pdf19/K191321.pdf ; https://medicalvisiononline.com/wp-content/uploads/2022/08/Brochure-Primelase.pdf

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf20/K201594.pdf

  9. October 6, 2026

    fda status batch 02 platform indications evidence

    Claim-specific evidence; not a whole-profile verification.

    Source: https://www.accessdata.fda.gov/cdrh_docs/pdf19/K191321.pdf

  10. October 6, 2026

    FDA indication

    Source: Catalog update

  11. October 6, 2026

    FDA source URL

    https://www.accessdata.fda.gov/cdrh_docs/pdf19/K191321.pdf

    Source: Catalog update

  12. September 4, 2026

    treatment pricing

    Unsourced evaluative sentence removed under the opinion-layer gate.

    Source: Catalog update — Wave D opinion-layer gate, 2026-09-04

  13. September 4, 2026

    science

    Unsourced evaluative sentence removed under the opinion-layer gate.

    Source: Catalog update — Wave D opinion-layer gate, 2026-09-04

  14. August 5, 2026

    Warranty & service

    Source: Catalog update

  15. August 1, 2026

    Record created

    Added to The Aesthetic Index — August 2026

    Source: The Aesthetic Index editorial

Cite this data: The Aesthetic Index, "Cocoon Medical Primelase Excellence/HR — pricing, FDA status and cost to own", aestheticindex.co (accessed November 23, 2026).

Get the full State of Aesthetic Devices 2026 report

A catalog of US-marketed aesthetic and wellness devices — preview it free.

Get the report

Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.