Head to head
CO2RE vs HELIX (2026)
Compare purchase costs, running costs and the evidence behind each device.
Read the comparison overview
- Purchase cost
- No new-price range is on file for either CO2RE or HELIX. Request current quotes to compare purchase costs.
- Practice fit
- Both are listed under CO2 fractional/ablative. Check each model’s US regulatory status and labeled indications for your intended use.
CO2 Fractional/Ablative
View full device profile →CO2 Fractional/Ablative
View full device profile →Price comparison
New price range
- Candela CO2RE
- Not published
- DEKA HELIX
- Not published
Used price reference
- Candela CO2RE
- $25k–$45kSource not documented
- DEKA HELIX
- Not published
Payback calculator
- Candela CO2RE
- View ROI calculator
- DEKA HELIX
- View cost details
Next step
Supplies & running costs
Supplies & restrictions
- Candela CO2RE
Supply pricing is not documented with a dated source yet. Request an itemized supply quote.
View running-cost details- DEKA HELIX
Supply details not yet documented.
View running-cost details
FDA status & indications
FDA status & indication
- Candela CO2RE
Record scope: K181523 names the CO2RE Laser System and includes separate standard, fractional and surgical handpiece indications. K151655 is the earlier cited platform record. Included handpieces and applicable labeling determine scope; a platform clearance is not a statement that every accessory is supplied.
Read FDA indication wording
“The CO2RE is indicated for use in surgical applications requiring the ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: aesthetic surgery (dermatology and plastic surgery), podiatry, gynecology, neurosurgery, orthopedics (soft tissue), arthroscopy (knee). The CO2RE is indicated for dermatological procedures requiring ablation, coagulation and resurfacing of soft tissue, including skin. The Standard Handpiece of the CO2RE System is indicated for the following: Dermatology & Plastic Surgery The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of: x laser skin resurfacing x laser dermabrasion x laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) for the treatment of: x wrinkles, rhytids, and furrows (including fines lines and texture irregularities) Clinical literature demonstrates that skin resurfacing of wrinkles, rhytids, and furrows with CO2 laser increases the amount of sub-epidermal collagen.”
- DEKA HELIX
- FDA record cited — see scopeK222221
Record scope: 510(k): K222221 (decision 4 Jan 2023). Checked 4 Sep 2026.
Read FDA indication wording
“The Helix Laser System with its accessories is intended for use in surgical applications requiring the ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: aesthetic surgery (dermatology and plastic surgery). CO2 Handpieces The Helix CO2 handpieces with wavelength of 10600 nm are indicated for use for the particular indications as follows: Dermatology & Plastic Surgery The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of: * laser skin resurfacing * laser derm-abrasion * laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) of soft tissue for the reduction, removal, and/or treatment of: warts, acne scars, nevi epidermal, syringoma. Vaporization/coagulation of warts. Scanning unit The Helix Scanning unit, with wavelength of 10600 nm is indicated for: •Laser skin resurfacing (ablation and/or vaporization) of soft tissue The Helix Scanning unit, with wavelength of 1570 nm, is indicated for: • Use in dermatological procedures requiring fractional skin resurfacing and coagulation of soft tissue The Helix Scanning unit, with wavelengths of 10600 nm & 1570nm is indicated for laser skin resurfacing (ablation and/or vaporization) of soft tissue.”
Which chains run each
Chain adoption
- Candela CO2RE
- 0 recorded pairings
- DEKA HELIX
- 0 recorded pairings
Chains using it
- Candela CO2RE
- —
- DEKA HELIX
- —
Approved reviews
- Candela CO2RE
- 0
- DEKA HELIX
- 0
Specs and platform
Manufacturer
- Candela CO2RE
- Candela
- DEKA HELIX
- DEKA
Built by (OEM)
- Candela CO2RE
- Syneron Medical Ltd.
- DEKA HELIX
- DEKA M.E.L.A. S.r.l.
Category
- Candela CO2RE
- CO2 Fractional/Ablative
- DEKA HELIX
- CO2 Fractional/Ablative
Technology
- Candela CO2RE
- Fractional CO2 10600nm dual-ring scanning (CO2 fractional)
- DEKA HELIX
- Combined CO2 and non-ablative resurfacing platform (CO2 fractional)
Launch year
- Candela CO2RE
- 2011
- DEKA HELIX
- —
Status
- Candela CO2RE
- Current
- DEKA HELIX
- Current
Manufacturing relationship evidence
- Candela CO2RE
- No separate manufacturing-relationship record linked.
- DEKA HELIX
- No separate manufacturing-relationship record linked.
Current alternatives
Current catalog models in related categories. Confirm availability and configuration with the supplier.
Alma Hybrid
CO2 Fractional/Ablative
New-equipment price not yet documented.
Cynosure Lutronic eCO2 3D
CO2 Fractional/Ablative
New-equipment price not yet documented.
DEKA SmartXide Punto
CO2 Fractional/Ablative
New-equipment price reference
$60k–$90k
Source not documentedCheck the profile for configuration and price details.
DEKA SmartXide Tetra PRO (CoolPeel)
CO2 Fractional/Ablative
New-equipment price reference
$90k–$125k
Source not documentedCheck the profile for configuration and price details.
Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.