Skip to content

Head to head

Pixel CO2 vs CO2RE (2026)

Compare purchase costs, running costs and the evidence behind each device.

Read the comparison overview
Purchase cost
No new-price range is on file for either Pixel CO2 or CO2RE. Request current quotes to compare purchase costs.
Practice fit
Both are listed under CO2 fractional/ablative. Check each model’s US regulatory status and labeled indications for your intended use.

CO2 Fractional/Ablative

View full device profile →

CO2 Fractional/Ablative

View full device profile →

Price comparison

New price range

Alma Pixel CO2
Not published
Candela CO2RE
Not published

Used price reference

Alma Pixel CO2
$12k–$25kSource not documented
Candela CO2RE
$25k–$45kSource not documented

Payback calculator

Alma Pixel CO2
View ROI calculator
Candela CO2RE
View ROI calculator

Next step

Alma Pixel CO2

Explore this model’s specs and owner reviews. For new-equipment inquiries, browse current models.

Browse current models
Candela CO2RE

Supplies & running costs

Supplies & restrictions

Alma Pixel CO2

Supply details not yet documented.

View running-cost details
Candela CO2RE

Supply pricing is not documented with a dated source yet. Request an itemized supply quote.

View running-cost details

FDA status & indications

FDA status & indication

Alma Pixel CO2
FDA record cited — see scopeK103501, K250071

Record scope: K103501 names the Alma Lasers Pixel CO2 Laser System. The later K250071 names the Alma FemiLift Pixel CO2 Laser System, a specific configuration; its scope should not be generalized to every Pixel CO2 unit. See the selected system's applicators and labeling. Indication scope checked October 2, 2026; see the full labeling for the selected configuration.

Read FDA indication wording
“The Alma Lasers Pixel CO2TM Laser System, Delivery Devices and Accessories are intended for use in surgical applications requiring the ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: aesthetic surgery (dermatology and plastic surgery), podiatry, gynecology, neurosurgery, orthopedics (soft tissue), arthroscopy (knee). The Alma Lasers Pixel CO2TM Laser System is cleared for use for the particular indications as folIlows: Dermatology & Plastic Surgery The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of:- * laser skin resurfacing * laser derm-abrasion * laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) for the treatment of:, * wrinkles, rhytids, and furrows (including fines lines and texture irregularities) Clinical literature demonstrates that skin resurfacing of wrinkles, rhytids, and furrows With CO2 laser increases the amount of sub-epidermal collagen.”
Candela CO2RE
FDA record cited — see scopeK151655, K181523

Record scope: K181523 names the CO2RE Laser System and includes separate standard, fractional and surgical handpiece indications. K151655 is the earlier cited platform record. Included handpieces and applicable labeling determine scope; a platform clearance is not a statement that every accessory is supplied.

Read FDA indication wording
“The CO2RE is indicated for use in surgical applications requiring the ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: aesthetic surgery (dermatology and plastic surgery), podiatry, gynecology, neurosurgery, orthopedics (soft tissue), arthroscopy (knee). The CO2RE is indicated for dermatological procedures requiring ablation, coagulation and resurfacing of soft tissue, including skin. The Standard Handpiece of the CO2RE System is indicated for the following: Dermatology & Plastic Surgery The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of: x laser skin resurfacing x laser dermabrasion x laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) for the treatment of: x wrinkles, rhytids, and furrows (including fines lines and texture irregularities) Clinical literature demonstrates that skin resurfacing of wrinkles, rhytids, and furrows with CO2 laser increases the amount of sub-epidermal collagen.”

Which chains run each

Chain adoption

Alma Pixel CO2
0 recorded pairings
Candela CO2RE
0 recorded pairings

Chains using it

Alma Pixel CO2
—
Candela CO2RE
—

Approved reviews

Alma Pixel CO2
0
Candela CO2RE
0

Specs and platform

Manufacturer

Alma Pixel CO2
Alma
Candela CO2RE
Candela

Built by (OEM)

Alma Pixel CO2
Alma Lasers Ltd.
Candela CO2RE
Syneron Medical Ltd.

Category

Alma Pixel CO2
CO2 Fractional/Ablative
Candela CO2RE
CO2 Fractional/Ablative

Technology

Alma Pixel CO2
10,600 nm RF-excited CO2 laser with fractional scanner or pixel delivery, focusing applicators and an optional iPixel roller; confirm the included accessories. (CO2 fractional)
Candela CO2RE
Fractional CO2 10600nm dual-ring scanning (CO2 fractional)

Launch year

Alma Pixel CO2
2009
Candela CO2RE
2011

Status

Alma Pixel CO2
Legacy-used-market
Candela CO2RE
Current

Manufacturing relationship evidence

Alma Pixel CO2
No separate manufacturing-relationship record linked.
Candela CO2RE
No separate manufacturing-relationship record linked.

Current alternatives

Current catalog models in related categories. Confirm availability and configuration with the supplier.

Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.