Head to head
OmniMax S4 vs V30 (2026)
Compare purchase costs, running costs and the evidence behind each device.
Read the comparison overview
- Purchase cost
- Catalog new-price ranges: OmniMax S4, $60k–$90k; V30, $50k–$80k. Check the source notes and request current quotes.
- Practice fit
- Both are listed under IPL multi-app platform. Check each model’s US regulatory status and labeled indications for your intended use.
IPL multi-app platform
View full device profile →IPL multi-app platform
View full device profile →Price comparison
New price range
- SharpLight OmniMax S4
- $60k–$90kSource not documented
- Viora V30
- $50k–$80kSource not documented
Used price reference
- SharpLight OmniMax S4
- $25k–$45kSource not documented
- Viora V30
- $20k–$35kSource not documented
Payback calculator
- SharpLight OmniMax S4
- View ROI calculator
- Viora V30
- View ROI calculator
Next step
Supplies & running costs
Supplies & restrictions
- SharpLight OmniMax S4
Supply details not yet documented.
View running-cost details- Viora V30
Supply details not yet documented.
View running-cost details
FDA status & indications
FDA status & indication
- SharpLight OmniMax S4
- FDA record cited — see scopeK233304
Record scope: K233304, decided December 22, 2023, covers the Omnimax S3/S4 series and adds optional RF functionality. RF indications include mild-to-moderate facial wrinkles and rhytids. The older RF exclusion on the manufacturer’s US webpage conflicts with this record; verify the offered configuration against current labeling.
Read FDA indication wording
“The Omnimax Device Series along with its optional Handpieces, uses IPL, IR, Laser and RF technologies and is intended for use in aesthetic and cosmetic applications and in selective treatments in medical specialties of dermatology, through the transmission of energy to human skin. Intense Pulsed Light (IPL-DPC) with 415 – 1200 nm wavelengths (with and without contact-cooling) handpieces are indicated for: • Hair removal and Permanent Hair Reduction in all skin types (I-V) to the Fitzpatrick scale – Recommended wavelengths in the range of 635-950 nm, 730-950 nm or 580-950 nm. • Flow Mode is suitable for Fitzpatrick skin types I-VI. Recommended wavelength: 635nm-950nm. • Treatment of Benign Pigmented Epidermal and Cutaneous Lesions including warts, scars and striae in all skin types (I-VI) to the Fitzpatrick scale – Recommended wavelength in the range of 580-950 nm. • Treatment of Pigmented and Vascular Lesions in all skin types (I-VI) to the Fitzpatrick scale – Recommended wavelength in the range of 535-950 nm. • Treatment of Benign Pigmented Epidermal, Cutaneous and Vascular Lesions including warts, scars and striae in skin types (I-V) to the Fitzpatrick scale – Recommended wavelength in the range of 535-680 nm & 860-1200nm. • Treatment of Inflammatory Acne (acne vulgaris) in skin types (I-V) to the Fitzpatrick scale – Recommended wavelength in the range of 415-950 nm. Infrared (IR) with 850 – 1750 nm wavelengths (with contact cooling) handpieces is indicated for: • Dermatologic Treatment such as, but not limited to: photocoagulation of soft tissue (Scars, Wrinkles, Rhytids and Periorbital Wrinkles). […]”
- Viora V30
Record scope: K162363 explicitly names V30 and the V-Form BC Medium applicator; its enclosure specifies V-Form Small, Medium and Large applicators. K133837 is the earlier V-Total predicate. Scope depends on the installed handpiece; RF/massage labeling is not blanket clearance for fat reduction or all platform functions.
Read FDA indication wording
“The Viora V-total 7"' isintended for dermatological procedures. The ST handpiece is indicated for the treatment of relief of minor muscle aches and pain, relief of muscle spasm and temporary improvement of local blood circulation. The IPL handpiece with wavelengths 415-l200nm (with 5 different filters) is indicated for the treatment of:. * Moderate inflammatory acne vulgaris. * Benign pigmented epidermal lesions including dyschromia, hyperpigmentation, melasrna, and ephelides (freckles). * Cutaneous lesions including warts, scars and striae. "Benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacca, erythema of rosacca, angiomnas and spider angiomnas, poikiloderma of Civatte and venous malformations. * Removal unwanted hair. It is also intended for permanent reduction in unwanted hair. Permanent hair reduction is defined as the long-term stable reduction inthe number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regimen. The Nd:YAG Laser handpiece with wavelength 1064 nm comes with 4 different applicator spot diameters: 2x4, 3.5, 5.5 and 9.5 mm. The three smaller spot sizes (2x4, 3.5, 5.5 mm) are intended for: - Benign vascular lesions such as, but not limited to treatment of: port wine stains, hemangiomas, Warts, superficial and deep telangiectasias (venulectasias). reticular veins (0. 1-4.0mmn dia.) of the leg, rosace, venus lake, leg veins, spider veins, poikiloderma of civatte and angiomas. * Benign cutaneous lesions, such as, but not limited to: warts, scars, striae and psoriasis. * Benign pigmented lesions such as, but not limited to: lentigos (age spots), solar lentigos (sun spots), cafe-aulait macules, seborrheic keratosis, nevi and nevus of One, chloasma, verrucae, skin tags and keratosis. - Pigmented lesions to reduce lesion size, for patients with lesions that would potentially benefit from aggressive treatment, and for patients with lesions that have not responded to other laser treatments. ' The non-ablative treatment of facial wrinkles, such as, but not limited to: periocular wrinkles and perioral wrinkles. "The handpiece with a spot size of 9.5 mm is also intended for treatment of: Laser skin resurfacing procedures for the treatment of: acne scars and wrinkles. Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral pant of the scar.”
Which chains run each
Chain adoption
- SharpLight OmniMax S4
- 0 recorded pairings
- Viora V30
- 0 recorded pairings
Chains using it
- SharpLight OmniMax S4
- —
- Viora V30
- —
Approved reviews
- SharpLight OmniMax S4
- 0
- Viora V30
- 0
Specs and platform
Manufacturer
- SharpLight OmniMax S4
- SharpLight
- Viora V30
- Viora
Built by (OEM)
- SharpLight OmniMax S4
- SharpLight Technologies
- Viora V30
- Viora Ltd.
Category
- SharpLight OmniMax S4
- IPL multi-app platform
- Viora V30
- IPL multi-app platform
Technology
- SharpLight OmniMax S4
- IPL-DPC, infrared, RF and laser handpieces (IPL)
- Viora V30
- Modular RF, IPL and Nd:YAG platform; V-Form combines RF with massage. (IPL)
Launch year
- SharpLight OmniMax S4
- 2016
- Viora V30
- 2018
Status
- SharpLight OmniMax S4
- Current
- Viora V30
- Current
Manufacturing relationship evidence
- SharpLight OmniMax S4
- No separate manufacturing-relationship record linked.
- Viora V30
- No separate manufacturing-relationship record linked.
Current alternatives
Current catalog models in related categories. Confirm availability and configuration with the supplier.
Lumenis Stellar M22
IPL multi-app platform
New-equipment price not yet documented.
Venus Versa Pro
IPL multi-app platform
New-equipment price not yet documented.
InMode Envision
IPL multi-app platform
New-equipment price not yet documented.
InMode Optimas
IPL multi-app platform
New-equipment price not yet documented.
Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.