- Purchase cost
- No new-price range is on file for either Splendor X or Clarity. Request current quotes to compare purchase costs.
- Practice fit
- Both are listed under dual-wavelength laser. Check each model’s US regulatory status and labeled indications for your intended use.
Dual-wavelength laser
View full device profile →Dual-wavelength laser
View full device profile →Price comparison
New price range
- Lumenis Splendor X
- Not published
- Lutronic Clarity
- Not published
Used price reference
- Lumenis Splendor X
- $70k–$110kSource not documented
- Lutronic Clarity
- $18,975 (historical dealer asking price; sold listing)Reported source: Used listing · Oct 2, 2026
Payback calculator
- Lumenis Splendor X
- View ROI calculator
- Lutronic Clarity
- View ROI calculator
Next step
Explore this model’s specs and owner reviews. For new-equipment inquiries, browse current models.
Browse current modelsSupplies & running costs
Supplies & restrictions
- Lumenis Splendor X
Read supply costs & requirements
No per-treatment disposable. The recurring cost is wear parts — handpiece lenses, flashlamp, protective windows, ceramic reflector, Nd:YAG and alexandrite rods, fibre window. Current US manufacturer wear-part pricing has not been verified here and the figures previously shown carried no dated source.
Dealer quote · Aug 30, 2026
View running-cost details- Lutronic Clarity
Supply details not yet documented.
View running-cost details
FDA status & indications
FDA status & indication
- Lumenis Splendor X
Read FDA indication wording
“The Nd:YAG 1064 Laser is intended for: • Removal of unwanted hair, for stable long term or permanent hair reduction and for treatment of Pseudofolliculitis barbae (PFB). Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime. The lasers are indicated on all skin types, such as Fitzpatrick I-VI, including tanned skin. • Photocoagulation and hemostasis of benign pigmented and vascular lesions such as, but not limited to, port-wine stains, hemangioma, warts, telangiectasia, rosacea, venous lake, leg veins and spider veins. • Coagulation and hemostasis of soft tissue. • Treatment of benign pigmented lesions such as, but not limited to, lentigos (age spots), solar lentigos (sunspots), cafe au lait macules, seborrheic keratosis, nevi, chloasma, verrucae, skin tags, keratosis, tattoos (significant reduction in the intensity of black and/or blue-black tattoos) and plaques. The laser is indicated for benign pigmented lesions to reduce lesion size, for patients with benign lesions that would potentially benefit from aggressive treatment, and for patients with benign lesions that have not responded to other laser treatments. • Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral part of the scar. • Treatment of wrinkles. • Temporary increase of clear nail in patients with onychomycosis (e.g., dermatophytes, Trichophyton rubrum and T. mentagrophytes, and/or yeast Candida Albicans, etc.). The Alexandrite 755 laser is intended for: • Temporary hair reduction. • Stable long-term or permanent hair reduction through selective targeting of melanin in hair follicles. Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime. On all skin types, such as Fitzpatrick I – VI, including tanned skin. • Treatment of benign pigmented lesions. • Treatment of wrinkles. • Photocoagulation of dermatological benign vascular lesions (such as port-wine stains, hemangiomas, telangiectasias).”
- Lutronic Clarity
- FDA record cited — see scopeK130199
Record scope: K130199 names CLARITY LPC, not CLARITY II. It has separate 755 nm and 1064 nm indication lists, including hair reduction in Fitzpatrick I–VI. That labeling is not a guarantee of equal risk or results across skin types; confirm wavelength, settings and model.
Read FDA indication wording
“The CLARITY LPC Laser System is indicated for the following: 755nm: The CLARITY LPC Laser System is indicated for temporary hair reduction. Stable long-term or permanent reduction through selective targeting of melanin in hair follicles. Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime. On all skin types (Fitzpatrick I-VI) including tanned skin. Treatment of benign pigmented lesions. Treatment of wrinkles. The photocoagulation of dermatological vascular lesions (such as port-wine stains, hemangiomas, telangiectasias). 1064nm: The CLARITY LPC Laser System is indicated for the removal of unwanted hair, for stable long term or permanent hair reduction and for treatment of PFB. Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime. The lasers are indicated on all skin types Fitzpatrick I-VI including tanned skin. Photocoagulation and hemostasis of pigmented and vascular lesions such as but not limited to port wine stains, hemangioma, warts, telangiectasia, rosacea, venous lake, leg veins and spider veins. Coagulation and hemostasis of soft tissue. Benign pigmented lesions such as, but not limited to, lentigos (age spots), solar lentigos (sun spots), cafe au lait macules, seborrheic keratoses, nevi, chloasma, verrucae, skin tags, keratoses, tattoos (significant reduction in the intensity of black and/or blue-black tattoos) and plaques. The laser is indicated for pigmented lesions to reduce lesion size, for patients with lesions that would potentially benefit from aggressive treatment, and for patients with lesions that have not responded to other laser treatments. The laser is also indicated for the reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral part of the scar. Treatment of wrinkles.”
Which chains run each
Chain adoption
- Lumenis Splendor X
- 0 recorded pairings
- Lutronic Clarity
- 0 recorded pairings
Chains using it
- Lumenis Splendor X
- —
- Lutronic Clarity
- —
Approved reviews
- Lumenis Splendor X
- 0
- Lutronic Clarity
- 0
Specs and platform
Manufacturer
- Lumenis Splendor X
- Lumenis
- Lutronic Clarity
- Lutronic
Built by (OEM)
- Lumenis Splendor X
- Lumenis Be Ltd.
- Lutronic Clarity
- Lutronic Corporation
Category
- Lumenis Splendor X
- Dual-wavelength laser
- Lutronic Clarity
- Dual-wavelength laser
Technology
- Lumenis Splendor X
- 755+1064nm BLEND X square spot
- Lutronic Clarity
- 755nm alex + 1064nm Nd:YAG (Nd:YAG)
Launch year
- Lumenis Splendor X
- 2018
- Lutronic Clarity
- 2015
Status
- Lumenis Splendor X
- Current
- Lutronic Clarity
- Discontinued
Manufacturing relationship evidence
- Lumenis Splendor X
- No separate manufacturing-relationship record linked.
- Lutronic Clarity
- No separate manufacturing-relationship record linked.
Current alternatives
Current catalog models in related categories. Confirm availability and configuration with the supplier.
Cutera Excel HR
Dual-wavelength laser
New-equipment price reference
$95k–$135k
Source not documentedCheck the profile for configuration and price details.
Lutronic Clarity II
Dual-wavelength laser
New-equipment price not yet documented.
Quanta System Duetto MT / MT Evo
Dual-wavelength laser
New-equipment price not yet documented.
Quanta System Thunder (MT)
Dual-wavelength laser
New-equipment price not yet documented.
Device and company names are trademarks of their respective owners. The Aesthetic Index is not affiliated with or endorsed by any manufacturer, distributor or lender named here, except as disclosed. Price figures are references, not current offers. Check each device’s source notes. Not medical, legal or regulatory advice.